Bas Sys Trim CHK
Max:450.000
Min:6.00000
Qmax(m
3
/h)
200.000
100.000
Qmax(m
3
/h)
Bas Sys Trim CHK
200
100
Qmax(m
3
/h)
OK:C/CE
CANCEL:
→
Bas Sys Trim
CHK
Low Cutoff %
Max Limit%
Limit Time(S)
Direction
200
Basic Setup
Bas Sys Trim
CHK
PV Decimal
Total Decimal
Damping(s)
Lcd Rotate
SYSTEM SETUP
Bas Sys Trim
CHK
Signal
→
Pulse Output
→
MODBUS
Output
→
Clear Total
Load Settings
SYSTEM SETUP
Bas Sys Trim
CHK
Signal
→
Pulse Output
→
MODBUS
Output
→
Clear Total
Load Settings
Click “C/CE” three times to back measurement mode, you also
can continue other operation.
6.) Small flow termination%(low %)
The parameters on the display and output are valid. When the traffic signal to terminate
below the low flow rate (unit%) of the settings to set the value of the The signal will be
removed, display and output to zero. The termination of the small percentage is relative to
the scale in terms of flow rate settings. Set As follows
Steps
Operation instructions
Interface show
Steps
Operation instructions
Interface show
Click “→” into QMAX menu to setup
Max Flow by “→” and” ↓” key
Modify value
Current value
Click “C/CE” to quit setup menu ,LCD
show confirm menu
Click “C/CE” ,confirm and save
configure ,after return configure option
menu,(click “→” to give up modify.)
Click “C/CE” two times from
measurement mode into
configuration menu
Click “→” to choice “sys” item
Click “↓” to choice “Signal” item
TRANSIMITTER
CONVERT PARTS
26