3. Select menu item Measurement mode
(
BAS
)
Basic Configuration
(
SYS
)
System Configuration
(
TRIM
)
Instrument Calibration
(
CHK
)
Instrument Test
(BAS)Basic Configuration
Damping(s)
(
0.1~99.1
)
(SYS)System Configuration
Signal
Pulse Output
MODBUS Output
HART Address
Clear Total
Load Settings
SYSTEM SETUP
Bas Sys Trim
CHK
Signal
→
Pulse Output
→
MODBUS
Output
→
Clear Total
Load Settings
Tube Trim
Zero Trim
TRANSMITTER TRIM
BAS SYS TRIM CHK
Tube Trim
→
Loop Trim
→
Zero Trim
Toal Preset
K Character
→
→
Loop Test
Pulse Test
Check frequency output
OUTPUT CHECK
BAS SYS TRIM CHK
Loop test
Pulse Test
Basic Setup
Bas Sys Trim
CHK
PV Decimal
Total Decimal
Damping(s)
Lcd Rotate
-8888.8
REVISION B50.2
Enter Setup ?
YES:C/CE NO:
C/CE
PV Decimal (1
、
2
、
3)
Totoal Decimal
(
1
、
2
、
3
)
Lcd Rotate (0
、
+90
、
180
、
-90
)
(TRIM) Instrument Calibration
Loop Trin
K Character
Manual Adjust
(CHK)Instrument Test
4-20mA test
Enter the parameter setting Press "C / CE “bond. Appears in
Figure interface, select" C / CE "will enter the menu:
Click”→” to quit menu
TRANSIMITTER
20
CONVERT PARTS