Ⅰ.
Installation
2.) Installation environment
2
)
The working conditions:
:
a) ambient temperature:-20°C
~
55°C
b) relative humidity: 5% -90%
c) power supply
AC Power Supply:85VAC
~
265VAC
,
50Hz
DC Power Supply:18VDC
~
36VDC
Rated Power:<10VA
(
include sensor
)
1. Working condition
2. Installation Notes
Transmitter’s configuration in accordance with the contract requirements, run the data set in
accordance with contract requirements. Users can check the meter nameplate to confirm
that the instrument provided by the model and instrument operating parameters set. It can
be put into use after connect power. In order to ensure your system run on normal
operation, make sure that the sensor measurement is full of medium channels
Our company electromagnetic flowmeter is dedicated to conductive fluid (conductivity ≥ 5μS/cm,
water ≥ 20μS / cm) the volume of flow measurement.
Flowmeter installation and usage should be in strict accordance with the specification, and to comply
with the relevant national standards, safety requirements and accident prevention requirements.
MF7200 electromagnetic flow converter directly connected with the electromagnetic flow sensor
compact into one body
It should avoid large temperature changes. If the meter installed by the thermal radiation Plateau,
please provide the thermal isolation or ventilation. Instrumentation installed in the switch box, there
should be appropriate measures of net and ventilation are examples such as the fan. Compact
structure flow meter should give full consideration to the transmitter working environment
temperature.
1.
)
The working conditions of the reference test
:
a) operating temperature:20°C±2°C
b) relative humidity:45%
~
85%
c) the supply voltage:220VAC±2%
d) Power frequency:50Hz±5%
e) harmonic content:<5%
f) warm-up time:>15min
It should avoid in a strong corrosive atmospheric environment. Installation location should have
adequate ventilation. Protective properties of instruments should be maintained to prevent the
corrosive gases and moisture into the instrument cavity. It Should avoid direct sunlight, especially
the liquid crystal display part. Strong vibration should be avoided.
1. ) Environment temperature
3.) Installation methods
A compact body flowmeter transmitter and Sensor two parts is connected to the end before out
of factory, the user can be installed directly. Sub-constructer flowmeter for Transmitter and
sensors to be in two parts at field by the user through a dedicated cable (factory annex) to
connect. Part of the sensors installed on both glycosides, Transmitter are usually installed in the
indoor or meter box. The distance is shorter for better.