Flotec SCM 4 PLUS 115/122 Use And Maintenance Manual Download Page 11

9

GB

CH. 7 - STARTING THE UNIT

Before lowering the pump into the well it is necessary to control the direction of rotation of the motor to avoid
damaging the thrust bearing. If the direction of rotation is correct, the hydraulic performances of the pump are
compliant with those indicated in the catalogue. To perform this check it is necessary to start the pump with a partially
opened gate. When the water starts flowing in, further close the gate and verify that the pressure value is above the
one indicated on the nameplate. If this not occurs, the motor is rotated in the opposed direction. To resume the correct
direction of rotation, invert the two phases on the control panel. The motor of the pump should not rotate in the
opposite direction for above 30 seconds.
After verifying the direction of rotation, allow the pump to run reducing the opening of the valve to about half the
maximum opening, for about one minute.  Stop the pump to remove gas pockets from the hydraulic unit, since their
presence could prevent the correct lubrication of the shaft. This interval should always be below 5 minutes. After
performing this operation, restart the machine by gradually opening the delivery valve until all the sand has been
removed or has reached minimum levels (40 g/m3). If the well has been built and drained correctly, this operation can
be performed in about 20 minutes. After the completion of this phase, it is possible to connect the delivery hose of
the pump. Before starting the pump is final mode, check:
- the continuity of the electric circuit to make sure that no damages have occurred during the lowering in the well
- the insulation resistance to ground, that is the related value between the cable terminals and the drainage pipe
- the performances of the pump, that should always be within the operating range
- the value of the current supplied to the control board, that should always be below the one indicated on the motor
  nameplate
If necessary, partially open the gate or adjust the pressure switches. If abnormal operating conditions are reported
during the start-up phase, stop the machine, establish the cause and remove the pump from the well, if necessary.

WARNING

Use the hydraulic unit within the operating limits indicated
on the nameplate or the datasheet.

WARNING

Never run the pump in dry conditions, even for short
intervals of time.

WARNING

Do not run the pump with the interception valve on delivery
completely closed.

WARNING

Do not run the pump in the opposite direction for more than
30 seconds.

WARNING

Complete all the electric and mechanic connections before
starting the pump.

CH. 8 - MAINTENANCE AND TROUBLESHOOTING

Periodical maintenance should be performed according to the content of sand in water. In ordinary conditions, 

SCM

4 Plus® 

pumps do not require servicing. To  prevent possible failure, it is advisable to periodically control the flow rate

and current absorption. A fall below 50% in the flow rate, as compared to the rated value, indicates that the pump is
worn. Similarly, an increase of the current absorption above 5% indicates the presence of abnormal mechanical
failures in the pump and/or motors. In many cases, it is necessary to replace the worn parts, like impellers, O-rings

DANGER

Electric shock
risk

Before doing any operation, make sure machine is
disconnected from electric power supply.

4

GB

Electric connections must be carried out by skilled staff only, in accordance with the manufacturer's instructions
enclosed to the electric equipment and the motor. It is advisable to install a protection device upstream, of adequate
dimensions (in accordance with the current values indicated on the nameplate) to prevent voltage peaks and
overloads.
Cables should be selected in function of the absorption in Ampere, indicated on the nameplate. Cables should be
dimensioned in accordance to the power to transmit, of the distance from the control page and the starting system
of the submersed motor. Cables should guarantee a submersed operation, have waterproof joints and show no signs
of abrasions or holes.
The control board should be equipped with all the protection devices and equipment to manage and drive the hydraulic
unit. More specifically, it is necessary to guarantee a protection against overcurrent and short circuits.  Protections
against the loss of phases, the lowering of voltage and the lack of water in the well are recommended but not
compulsory.

Summary of Contents for SCM 4 PLUS 115/122

Page 1: ...anleitung 16 Manual de uso y manutenci n 21 Handleiding voor gebruik en onderhound 26 SCM 4 PLUS GB I F D E NL Bycnherwbb gj ecnfyjdrt Bycnherwbb gj ecnfyjdrt Bycnherwbb gj ecnfyjdrt Bycnherwbb gj ecn...

Page 2: ...ene gjengitt nedenfor EU VAATIMUSTENMUKAISUUSVAKUUTUS Yhti Pentair International Sarl ilmoittaa omalla vastuullaan ett alla osoitetut tuotteet ovat oleellisten turvallisuus ja terveydensuojelu vaatimu...

Page 3: ...trasporto eseguire le seguenti verifiche Caro cliente Ci congratuliamo con Lei per l acquisto di questo prodotto Come tutti gli articoli FLOTEC questo prodotto stato disegnato secondo i principi tecn...

Page 4: ...0 mm 100 mm 100 mm Massima temperatura del liquido pompato 35 C 35 C 35 C Massimo numero di avviamenti orari equamente distribuiti 20 20 20 Livello di pressione sonora inferiore a 70 dB A valori di em...

Page 5: ...cessivo emungimento In ogni caso il livello del pozzo non deve mai scendere sotto la camera aspirante per evitare il grippaggio delle boccole guida ed il surriscaldamento del motore Il cavo di aliment...

Page 6: ...na individuare la causa eventualmente risollevando l elettropompa dal pozzo Cap 8 MANUTENZIONE E RICERCA GUASTI La manutenzione periodica in stretta dipendenza con la presenza di sabbia nell acqua In...

Page 7: ...di rotazione errato versioni trifasi 2 Perdite nell impianto 3 Filtro intasato o elettropompa insabbiata 4 Elettropompa usurata 5 Prevalenza manometrica calcolata in modo errato 1 Scambiare 2 fasi di...

Page 8: ...ES SCM 4 Plus pumps can be supplied with or without electric motor This booklet supplies all the information concerning the use and maintenance of these machines SCM 4 Plus pumps are submersed The mul...

Page 9: ...mum temperature of the pumped fluid 35 C 35 C 35 C Maximum number of starts per hour uniformly distributed 20 20 20 Sound pressure level less than 70 dB A sound emission values obtained in conformity...

Page 10: ...tioning the pump it is necessary to take into account the lowering of the water level that can originate from seasonal factors or from an excessive stratum extraction The well level should never fall...

Page 11: ...machine establish the cause and remove the pump from the well if necessary WARNING Use the hydraulic unit within the operating limits indicated on the nameplate or the datasheet WARNING Never run the...

Page 12: ...FLOW RATES AND HEADS 1 IIncorrect direction of rotation three phase versions 2 Leakage in the installation 3 Filter is clogged or sand in electric pump 4 Electric pump worn out 5 The pressure head ha...

Page 13: ...Comme toutes les productions FLOTEC ce produit a t d velopp sur la base des toutes derni res technologies et est fabriqu en utilisant les l ments lectriques lectroniques les plus fiables et les plus m...

Page 14: ...50 gr m3 50 gr m3 Diam tre minimum du puits 100 mm 100 mm 100 mm Temp rature maxi du liquide pomp 35 C 35 C 35 C ombre maximum de d marrages par heure distrib gale distance 20 20 20 Niveau de pression...

Page 15: ...dessous de la chambre aspirante pour viter le gripage des bagues guidage et le surchauffement du moteur Le c ble d alimentation doit tre fix au moyen de bandelettes sp ciales tous les 2 3 m du tube L...

Page 16: ...NES L entretienp riodiqued pend troitementdelapr sencedesabledansl eau Dansdesconditionsnormales lespompesde la s rie SCM 4 Plus n ont besoin d aucun entretien Afin de pr venir les avaries possibles i...

Page 17: ...ELEVATION ET DE DEBITS FAIBLES 1 Le sens de rotation n est pas bon versions triphas es 2 Fuites au niveau de l installation 3 Le filtre est sale ou la pompe est pleine de sable 4 Pompe us e 5 Pr valen...

Page 18: ...romotor geliefert werden das vorliegende Informationsbuch stellt alle Hinweise zur Verf gung die den Gebrauch und die Wartung dieser Maschinen betreffen Die Pumpen der Serien SCM 4 Plus sind Unterwass...

Page 19: ...von Hand berpr fen sicherstellen da das Anschlu st ck und die Anschlu fl che gereinigt sind den Pumpenk rper mit dem Motor verbinden dabei ist darauf zu achten da das elektrische Kabel korrekt in Ents...

Page 20: ...m anderen Ende des Rohrs befestigt wurde im Falle einer Installierung mit Gewinderohren wird an das obere Ende die entsprechende Gewindemanschette angebracht um ein eventuelles Verrutschen zwischen Ro...

Page 21: ...cht der Fall sein so dreht der Motor in verkehrter Richtung Um die korrekte Drehrichtung zu erreichen sind zwei Phasen an der Kommandotafel umzukehren Der Motor der Pumpe darf nicht l nger als 30 Seku...

Page 22: ...lokalisieren und den Schaden beheben 3 Die Pumpe berholen und oder ersetzen 4 Die Pumpe herausnehmen eine Kontrolle vornehmen die abgenutztenTeile ersetzen oder die Pumpe auswechseln 5 Die Kalkulation...

Page 23: ...alzada La bomba completa o la bomba idr ulica tiene que transportarse con medios aptos a su peso y dimensiones Se permite movimientos manuales exclusivamente cuando el peso por m quina no supera los...

Page 24: ...DEL MOTOR Ver fig 1 Todas las operaciones relativas a la instalaci n tienen que ser efectuadas con el grupo desconectado de la red de alimentaci n Las bombas de la serie SCM 4 PLUS y SA 6 han sido rea...

Page 25: ...arejo bajar todo en el pozo para que la brida apoye contra la abertura del pozo Prestar atenci n a la extremidad libre del cable para evitar que pueda caer en el pozo Conectar un segundo tramo del tub...

Page 26: ...e un funcionamiento anormal es indispensable parar la m quina individualizar la causa y eventualmente quitando la bomba del pozo CAP 8 MANUTENCI NY LOCALIZACI N DE PROBLEMAS El mantenimiento peri dico...

Page 27: ...n 3 Filtro obstruido o bomba tapada 4 Bomba desgastada 5 Altura manom trica err neamente calculada 1 Intercambiar 2 fases de alimentaci n en el tablero de mando 2 Localizar las p rdidas y reparar la...

Page 28: ...e waterspiegel met directe koppeling tussen de multistadium pompeenheid en de onder de waterspiegel werkende electrische motor HFD STK 2 TRANSPORT EN OPSLAG Elke machine wordt na de montage met maxima...

Page 29: ...diameter van de put 100 mm 100 mm 100 mm Maximale temperatuur van de gepompte vloeistof 35 C 35 C 35 C Maximum aantal keren opstarten per uur gelijkmatigverdeeld 20 20 20 Geluidsdrukniveau Lpa gelijk...

Page 30: ...n de put laat zakken moet men controleren dat de voedingskabels goed aan de klemmen van het controlepaneel zijn verbonden en dat de veiligheidsrelais overeenkomen met de opgegeven stroomwaarden Daarna...

Page 31: ...odig kan zijn om de pomp uit de put te trekken HFD STK 8 ONDERHOUD EN SCHADEONDERZOEK De noodzaak om onderhoud uit te voeren hangt nauw samen met de aanwezigheid van zand in het water In normale omsta...

Page 32: ...reservoir vervangen DE POMP GEEFT NIET VEEL WATER EN OOK NOG ONDER LAGE DRUK 1 De draairichting is verkeerd versies met drie fasen 2 Perdite nell impianto 3 Filtro intasato o elettropompa insabbiata 4...

Page 33: ...________________________________________________________________________________________________________ FLOTEC 1 1 2 1 3 2 4 2 5 2 6 3 7 4 8 4 1 SCM 4 Plus SCM 4 Plus 2 8 RUS...

Page 34: ...00 W 2150 W IP58 B IP58 B IP58 B IP68 B 41 90 mm 1 1 4 F 41 90 mm 1 1 4 F 41 90 mm 1 1 4 F 41 90 mm 1 1 4 4 500 l h 4 500 l h 6 900 l h 6 900 l h 56 m 75m 95 m 122 m 150 m 150 m 150 m 150 m H07 RNF 15...

Page 35: ..._____________________________________________________________________________________________________________ 15 16 SCM 4 PLUS 1 2 1 2 2 3 6 D 30 mA DIN VDE 0100T739 RUS...

Page 36: ...___________________________________________________________________________________________________________ 7 30 30 5 40 g m3 20 8 SCM4 Plus 50 5 RUS...

Page 37: ...___________________________________________________________________________________________ 2 3 1 2 3 4 5 1 2 3 4 5 1 2 3 1 5 2 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 7 8 1...

Page 38: ...55...

Page 39: ...isteiss jos sit ohjataan esimerkiksi k ytt m ll taajuusmuuttajaa jolla pumpun tuottopiste sovitetaan j rjestelm n tuottotarpeisiin Tietoja hy tysuhteen vertailuarvoista on saatavilla osoitteessa www e...

Page 40: ...vser ldre elektrisk och elektronisk utrustning och dess till mpning enligt nationell lagstiftning ska uttj nta elektriska verktyg sorteras separat och l mnas till milj v nlig tervinning Dotyczy tylko...

Page 41: ......

Page 42: ......

Page 43: ...mat riel employ La garantie se limite la r paration ou au remplacement dans les Centres d Assistance Autoris s par PENTAIR INTERNATIONAL S a r l de la pompe ou des pi ces dont on reconna t le dysfonc...

Page 44: ...t NL GARANTIEVOORWAARDEN E CONDICIONES DE GARANT A Este equipo est cubierto con garant a legal seg n las leyes y normas vigentes a la fecha y en el pa s de adquisici n con referencia a los da os y def...

Reviews: