Operation 

7

“ELECTRIC” LED: when lit indicates an electrical fault.
“HYDRAULIC” LED: when lit, indicates a hydraulic fault 
[

DRY RUN

]. If both ELECTRIC and HYDRAULIC LED’s 

are lit, operator intervention is required.
“AUTO-RESET” LED: indicates the pump is in AUTO-
RESET mode - will reset [

DRY RUN

] alarm ONLY.

LCD display presents two lines of information, 
as described below. The LCD is backlit and will 
automatically turn off after a preset time. Pressing any 
control panel button will ‘wake up’ the LCD.
NOTICE: Direct exposure of the LCD display to 
sunlight is not recommended. If the display temperature 
rises above 150°F (65°C), the display will blank. All 
programmed booster functions will continue to operate, 
however. Display information will reappear after its 
temperature drops sufficiently.

Initial Operation

To start the pump the first time after installation has 
been completed:
1.  Plug the pump into the outlet.
2.  The preset pressure is 60 PSI. To change the pressure 

setting, press SET (even while the pump is operating) 
until the desired pressure is displayed.

3.  Press the “ ” button to start the pump. The ‘LINE’ 

LED will become green and a bar graph shows 
power usage.

4.  The “ ” button is also used to stop the pump, 

if necessary

The pump will start and will continue to operate until 
several seconds after the system pressure has risen and 
flow has stopped (water demand ceases). The pump 
may not operate if there is no water demand, so open 
a nearby faucet to create the demand if you wish to 
test the booster. It may also not operate if the discharge 
pressure is equal to or greater than the selected pressure 
value - pump will go into standby mode.
NOTICEThis pump is NOT self-priming – it requires a 
minimal flow of water at the pump inlet to operate. This 
pump is intended for booster applications only.

Automatic Operation

The control board monitors discharge port pressure. 
Should that pressure descend below the selected 
value when a water demand occurs, the pump starts 
automatically pumping water to the selected pressure. 
Shortly after the water demand ceases, the pump 
turns off.

AUTO-RESET mode

The AUTO-RESET mode is factory set to the ON 
condition, which means that if the pump stops when a 
[

DRY RUN

] condition occurs, it will automatically begin 

running when the condition is corrected.

To turn AUTO-RESET mode OFF:
1.  Plug the pump into the outlet.
2.  Press the RESET button. The AUTO-RESET LED 

turns OFF.

While in AUTO-RESET mode and the pump stops due to 
lack of inlet water, this sequence is followed:
1.  The pump will attempt to restart after 1 minute.
2.  If a lack of water continues to be detected or if 

an electrical fault has been detected, the pump 
will stop.

3.  A new restart attempt will happen after 10 minutes, 

and then, respectively after 30, 60, and 120 minutes.

4.  After the fifth consecutive attempt, the pump is 

deactivated, the “LINE” LED turns off and [

DRY RUN

is displayed..

If the pump is deactivated (LINE LED off), investigate 
the cause of the problem (lack of water or electrical 
problem), resolve the problem, and perform a manual 
reset. See Troubleshooting.

Manual Reset

If either alarm LED is ON, the alarm status can be 
cleared at any time by pressing the RESET button, even 
if the controller is set to AUTO-RESET (the AUTO-RESET 
LED is ON).

Language

If you wish to select Spanish or French language 
narration in the LCD window:
1.   Press MENU until the LANGUAGE parameter is 

presented.

2.   EN (English) is default. ES is Spanish, FR is French.
3.   Press SET a number of times until the desired 

language is displayed.

Motor RPM

If you wish to view motor RPM, press the MENU 
button a number of times until “RPM” appears. RPM is 
displayed only in bar graph form. The display will revert 
to the main screen after a few seconds.

When Does The Pump Stop Operating?

Pressure Set-Point/No Flow: The pump will stop 
operating, the ‘LINE’ LED will turn orange, and “STBY” 
(standby) will be displayed on the LCD, after the system 
pressure is above the set pressure of the pump (50, 60 
or 70 PSI) for 60 seconds and there is no flow. This is 
normal operation.
Restart: A drop in pressure 5 psi below the starting 
pressure set-point will cause the pump to restart and 
the ‘LINE’ LED to turn green. The pump will continue to 
operate until several seconds after:
•  Outlet pressure reaches the set pressure of the pump 

(50, 60 or 70 PSI), and

•  The flow stops.

Summary of Contents for FP5010

Page 1: ...e Call 1 800 365 6832 English Pages 2 10 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages...

Page 2: ...l a pressure relief valve in the pump discharge line capable of passing the full pump flow at 100 psi 689 kPa If local code requires installation of a pressure relief valve capable of handling the ful...

Page 3: ...ore Contact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump...

Page 4: ...uilding and electrical codes when installing the pump Use rigid pipe when installing this pump Plumbing Pump only clean water with your booster pump To avoid clogging the pump and damaging the shaft s...

Page 5: ...emove a length of pipe from the main water supply line to allow installation of elbows for the pump See Figure 2 which depicts a typical installation The locations of the cuts must take into considera...

Page 6: ...PSI See Figure 3 b Press the button The pump will start 16 When the pump stops running after it shuts off automatically the system is at the selected pressure Inspect the pipe and fittings again for...

Page 7: ...tly after the water demand ceases the pump turns off AUTO RESET mode The AUTO RESET mode is factory set to the ON condition which means that if the pump stops when a DRY RUN condition occurs it will a...

Page 8: ...life of the bearings The pump seal is water cooled and self lubricating The motor is equipped with an auto reset thermal overload protector If the motor overheats the overload will disable the motor...

Page 9: ...Heat pit or pump house Pump does not deliver water to full capacity Steel piping if used is corroded or limed causing excess friction Replace with plastic or copper pipe where possible otherwise with...

Page 10: ...F 35 C Maximum Ambient Temperature 122 F 50 C Dimensions 14 high x 9 wide x 13 long Weight 17 lb 8 kg Incoming Household Pressure 20 PSI 30 PSI 40 PSI 50 PSI Booster pump set at Boosted Household Pre...

Page 11: ...pompe Si le code de plomberie local requiert l installation d une soupape de d charge prenant en charge un d bit inf rieur 100 lb po2 689 kPa respecter les exigences de ce dernier Risque d incendie ou...

Page 12: ...mpes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe des fi...

Page 13: ...lors de l installation de la pompe Utiliser des tuyaux rigides lors de l installation de la pompe Tuyauterie Utiliser la pompe auxiliaire seulement avec de l eau propre Pour viter d obstruer la pompe...

Page 14: ...de coudes pour la pompe Voir la figure 2 qui montre une installation typique L emplacement des coupes doit tenir compte de la dimension des coudes utilis s de la longueur des filets des joints filet...

Page 15: ...de nouveau le tuyau et les raccords la recherche de fuites d eau En cas de fuite appuyer sur le bouton d brancher la pompe fermer la soupape de la conduite principale d alimentation en eau ouvrir un r...

Page 16: ...n au niveau de l orifice de refoulement Si la pression est inf rieure au r glage s lectionn lorsqu il y a une demande en eau la pompe d marre automatiquement pour pomper l eau la pression s lectionn e...

Page 17: ...se tenant sur un plancher mouill ou humide Le moteur est lubrifi en usine pour la dur e de vie des roulements billes Le joint de l arbre de la pompe est refroidi l air et est autolubrifiant Le moteur...

Page 18: ...u le b timent o est situ e la pompe La pompe ne d bite pas au maximum Les tuyaux en acier le cas ch ant sont corrod s ou entartr s causant ainsi un frottement excessif Dans la mesure du possible rempl...

Page 19: ...9 cm de largeur x 33 cm de longueur 14 po x 22 9 cm x 33 cm Poids 8 kg 17 lb Pression d entr e de la r sidence 20 lb po2 30 lb po2 40 lb po2 50 lb po2 Pompe auxiliaire r gl e Surpression de la r siden...

Page 20: ...cales requieren la instalaci n de una v lvula de desahogo de presi n capaz de procesar el flujo total de la bomba a una presi n inferior a 100 psi 689 kPa cumpla con los requerimientos de las normas P...

Page 21: ...su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci...

Page 22: ...e tuber as r gidas en la instalaci n de esta bomba Plomer a S lo bombee agua limpia con su bomba reforzadora Para evitar obstruir la bomba y da ar la junta del eje no bombee agua que contenga part cul...

Page 23: ...ra la bomba Consulte la Figura 2 que ilustra una instalaci n t pica Las ubicaciones de los cortes deben tener en cuenta el tama o de los tubos acodados que se utilicen el largo de las roscas en las ju...

Page 24: ...i n seleccionada Inspeccione nuevamente la tuber a y los accesorios para verificar que no haya fugas Si aparece alguna fuga oprima el bot n desenchufe la bomba cierre la v lvula principal de suministr...

Page 25: ...o do de AUTO RESET AUTOREPOSICI N El modo de AUTO RESET est configurado de f brica en la posici n activada ON lo cual significa que si la bomba se detiene cuando ocurre una situaci n de marcha en seco...

Page 26: ...icante El motor viene provisto con un protector de sobrecarga t rmica de reposici n autom tica Si el motor se recalienta el dispositivo de sobrecarga t rmica desactivar el motor para impedir que se da...

Page 27: ...e la bomba La bomba no entrega agua a toda capacidad Tuber a de acero si se usa corro da u oxidada provocando demasiada fricci n Reemplazar con tuber as de pl stico o de cobre en donde sea posible de...

Page 28: ...0 C Dimensiones 14 altura x 9 ancho x 13 largo 35 5 cm x 22 9 cm x 33 cm Peso 17 lb 8 kg Presi n de entrada de la residencia 20 PSI 30 PSI 40 PSI 50 PSI Bomba reforzadora configurada para Presi n refo...

Reviews: