For parts or assistance, call Flotec Customer Service at 1-800-365-6832

Safety 2

Important Safety Instructions

SAVE THESE INSTRUCTIONS - This manual contains 
important instructions that should be followed during 
installation, operation, and maintenance of the product. 
Save this manual for future reference.

 This is the safety alert symbol. When you see this 

symbol on your pump or in this manual, look for one of 
the following signal words and be alert to the potential 
for personal injury!

 indicates a hazard which, if not avoided, will 

result in death or serious injury.

 indicates a hazard which, if not avoided, 

could result in death or serious injury.

  indicates a hazard which, if not avoided, 

could result in minor or moderate injury.
NOTICE addresses practices not related to 
personal injury.
The manufacturer cannot anticipate every possible 
circumstance that might involve a hazard. The warnings 
in this manual, and the tags and decals affixed to the unit 
are, therefore, not all-inclusive. If you use a procedure 
or operating technique that the manufacturer does not 
specifically recommend, you must satisfy yourself that it 
is safe for you and others. You must also make sure that 
the procedure or operating technique that you choose 
does not render the system unsafe.
To avoid risk of serious bodily injury and property 
damage, read and follow all safety instructions in this 
manual and on equipment carefully before installing this 
pump. Keep safety labels in good condition; replace if 
missing or damaged.

  Hazardous pressure . The pump body may 

explode if used to boost pressure above 100 psi  
(689 kPa). Do not use this pump with inlet pressure 
greater than 70 psi (483 kPa). If not already in the 
piping system, install a pressure relief valve in the pump 
discharge line capable of passing the full pump flow at 
100 psi (689 kPa). If local code requires installation of a 
pressure relief valve capable of handling the full pump 
flow at a pressure less than 100 psi (689 kPa), follow the 
code requirements.

 Risk of fire or explosion . To avoid risk of 

fire and explosion, Pump Water Only with this pump. Do 
not pump salt water, flammable liquids or chemicals. Do 
not use the pump near gas pilot lights or where chemical 
or gas fumes are present. Use of an electric pump with 
liquids other than water or in an atmosphere containing 
chemical or gas fumes may ignite those liquids or gases 
and cause injury or death due to an explosion and/
or fire.

  Burn hazard . If water is trapped in the 

pump during operation it may turn to steam. Trapped 
steam can lead to an explosion and burns. Never run the 
pump with the outlet closed or obstructed.

  Burn hazard . Do not touch an operating 

motor. Motors can operate at high temperatures. To avoid 
burns when servicing the pump, allow it to cool for 
20 minutes after shut-down before handling.

 Hazardous voltage . Can shock, burn or 

cause death. Ground the pump before connecting to a 
power supply. Disconnect the power before working on 
the pump, motor or tank.
•  Wear safety glasses at all times when working 

on pumps.

•  The pump is supplied with a 3-conductor grounding 

type cord. Connect only to a properly grounded, 
GFCI protected outlet. Do not lift the pump by the 
electrical cord. The pump and controller are non-
submersible. Keep the motor dry at all times. Do 
not wash the motor. Do not immerse. Protect the 
motor from wet weather. Unplug the pump before 
servicing. After the plug is pulled, let the pump cool 
for 20 minutes before attempting to work on it.

•  Do not use an extension cord.
•  Do not allow pump or any system component to 

freeze. To do so will void warranty.

•  Periodically inspect pump and system components.

Summary of Contents for FP5010

Page 1: ...e Call 1 800 365 6832 English Pages 2 10 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages...

Page 2: ...l a pressure relief valve in the pump discharge line capable of passing the full pump flow at 100 psi 689 kPa If local code requires installation of a pressure relief valve capable of handling the ful...

Page 3: ...ore Contact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump...

Page 4: ...uilding and electrical codes when installing the pump Use rigid pipe when installing this pump Plumbing Pump only clean water with your booster pump To avoid clogging the pump and damaging the shaft s...

Page 5: ...emove a length of pipe from the main water supply line to allow installation of elbows for the pump See Figure 2 which depicts a typical installation The locations of the cuts must take into considera...

Page 6: ...PSI See Figure 3 b Press the button The pump will start 16 When the pump stops running after it shuts off automatically the system is at the selected pressure Inspect the pipe and fittings again for...

Page 7: ...tly after the water demand ceases the pump turns off AUTO RESET mode The AUTO RESET mode is factory set to the ON condition which means that if the pump stops when a DRY RUN condition occurs it will a...

Page 8: ...life of the bearings The pump seal is water cooled and self lubricating The motor is equipped with an auto reset thermal overload protector If the motor overheats the overload will disable the motor...

Page 9: ...Heat pit or pump house Pump does not deliver water to full capacity Steel piping if used is corroded or limed causing excess friction Replace with plastic or copper pipe where possible otherwise with...

Page 10: ...F 35 C Maximum Ambient Temperature 122 F 50 C Dimensions 14 high x 9 wide x 13 long Weight 17 lb 8 kg Incoming Household Pressure 20 PSI 30 PSI 40 PSI 50 PSI Booster pump set at Boosted Household Pre...

Page 11: ...pompe Si le code de plomberie local requiert l installation d une soupape de d charge prenant en charge un d bit inf rieur 100 lb po2 689 kPa respecter les exigences de ce dernier Risque d incendie ou...

Page 12: ...mpes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe des fi...

Page 13: ...lors de l installation de la pompe Utiliser des tuyaux rigides lors de l installation de la pompe Tuyauterie Utiliser la pompe auxiliaire seulement avec de l eau propre Pour viter d obstruer la pompe...

Page 14: ...de coudes pour la pompe Voir la figure 2 qui montre une installation typique L emplacement des coupes doit tenir compte de la dimension des coudes utilis s de la longueur des filets des joints filet...

Page 15: ...de nouveau le tuyau et les raccords la recherche de fuites d eau En cas de fuite appuyer sur le bouton d brancher la pompe fermer la soupape de la conduite principale d alimentation en eau ouvrir un r...

Page 16: ...n au niveau de l orifice de refoulement Si la pression est inf rieure au r glage s lectionn lorsqu il y a une demande en eau la pompe d marre automatiquement pour pomper l eau la pression s lectionn e...

Page 17: ...se tenant sur un plancher mouill ou humide Le moteur est lubrifi en usine pour la dur e de vie des roulements billes Le joint de l arbre de la pompe est refroidi l air et est autolubrifiant Le moteur...

Page 18: ...u le b timent o est situ e la pompe La pompe ne d bite pas au maximum Les tuyaux en acier le cas ch ant sont corrod s ou entartr s causant ainsi un frottement excessif Dans la mesure du possible rempl...

Page 19: ...9 cm de largeur x 33 cm de longueur 14 po x 22 9 cm x 33 cm Poids 8 kg 17 lb Pression d entr e de la r sidence 20 lb po2 30 lb po2 40 lb po2 50 lb po2 Pompe auxiliaire r gl e Surpression de la r siden...

Page 20: ...cales requieren la instalaci n de una v lvula de desahogo de presi n capaz de procesar el flujo total de la bomba a una presi n inferior a 100 psi 689 kPa cumpla con los requerimientos de las normas P...

Page 21: ...su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci...

Page 22: ...e tuber as r gidas en la instalaci n de esta bomba Plomer a S lo bombee agua limpia con su bomba reforzadora Para evitar obstruir la bomba y da ar la junta del eje no bombee agua que contenga part cul...

Page 23: ...ra la bomba Consulte la Figura 2 que ilustra una instalaci n t pica Las ubicaciones de los cortes deben tener en cuenta el tama o de los tubos acodados que se utilicen el largo de las roscas en las ju...

Page 24: ...i n seleccionada Inspeccione nuevamente la tuber a y los accesorios para verificar que no haya fugas Si aparece alguna fuga oprima el bot n desenchufe la bomba cierre la v lvula principal de suministr...

Page 25: ...o do de AUTO RESET AUTOREPOSICI N El modo de AUTO RESET est configurado de f brica en la posici n activada ON lo cual significa que si la bomba se detiene cuando ocurre una situaci n de marcha en seco...

Page 26: ...icante El motor viene provisto con un protector de sobrecarga t rmica de reposici n autom tica Si el motor se recalienta el dispositivo de sobrecarga t rmica desactivar el motor para impedir que se da...

Page 27: ...e la bomba La bomba no entrega agua a toda capacidad Tuber a de acero si se usa corro da u oxidada provocando demasiada fricci n Reemplazar con tuber as de pl stico o de cobre en donde sea posible de...

Page 28: ...0 C Dimensiones 14 altura x 9 ancho x 13 largo 35 5 cm x 22 9 cm x 33 cm Peso 17 lb 8 kg Presi n de entrada de la residencia 20 PSI 30 PSI 40 PSI 50 PSI Bomba reforzadora configurada para Presi n refo...