Flotec Easy Sump FPRP3250C Owner'S Manual Download Page 3

For parts or assistance, call Flotec Customer Service at

1-800-365-6832

Installation

3

To reduce risk of electric

shock, pull plug before

servicing. This pump has not been investigated
for use in swimming pool areas. Pump is
supplied with a grounding conductor and
grounding-type attachment plug. Be sure it is
connected only to a properly grounded
grounding-type receptacle.
Where a 2-prong wall receptacle is
encountered, it must be replaced with properly
grounded 3-prong receptacle installed in
accordance with codes and ordinances that
apply.

13.  All wiring should be performed by a qualified

electrician.

14. Make certain power source conforms to

requirements of your equipment.

15. Protect electrical cord from sharp objects, hot

surfaces, oil, and chemicals. Avoid kinking cord.
Replace or repair damaged or worn cords
immediately.

16. Do not touch an operating motor. Modern motors

can operate at high temperatures.

17. Do not handle pump or pump motor with wet

hands or when standing on wet or damp surface,
or in water.

Hazardous voltage can shock,

burn or kill. If your basement

has water or moisture on floor, do not walk on wet
area until all power has been turned off. If shut-off
box is in basement, call electric company or hydro
authority to shut-off service to house, or call your
local fire department for instructions. Remove
pump and repair or replace. Failure to follow this
warning can result in fatal electrical shock.

Do not lift pump by power cord.

FOR EMERGENCY FLOODING 
SITUATIONS

Hazardous voltage. Can shock,

burn or kill. If your basement has water or
moisture on floor, do not walk on wet area until all
power has been turned off.

If shut-off box is in

basement, call electric company or hydro authority to
shut-off service to house, or call your local fire
department for instructions. Remove pump and
repair or replace. Failure to follow this warning can
result in fatal electrical shock.
1. Install the adapter and hose barb in the pump’s

check valve. Install the hose on the adapter and
clamp it.

2. Lift the cord and tape it to the pump’s discharge

pipe. Plug the pump and switch into a UL and/or
CSA approved type SJTW water resistant 
3-prong grounding-type  extension cord. The 

cord must be at least #14 AWG and not more than
100 feet long. Plugs and extension cord must be
kept out of the water.

3. Remove the old pump from the sump and set it

aside.

4. Lower the pump into the sump. Make sure the

power cord is long enough that the plug is out of
the water when the pump is running.

5. Run the hose out of the flooded area to an

adequate drain area.

6.

Risk of electrical shock.

Go to a dry area, remove wet

shoes and change wet clothing. WHEN YOU ARE
DRY, plug the extension cord into a grounded
electrical outlet (with a GFCI, if possible). DO
NOT STAND IN WATER TO PLUG IN THE PUMP.

7. National Electrical Code (NEC) and Canadian

Electrical Code (CEC) requirements prohibit the
use of an extension cord with this pump in a
permanent installation.
As soon as possible, remove the extension cord
and reinstall the pump as a permanent
replacement pump whose power cord connects
directly into a properly grounded grounding-type
receptacle. Install the pump in accordance with
the instructions, and in accordance with all codes
and ordinances that apply.

8. Monitor the pump’s operation. The pump will

automatically stop when the water level has
receded to the OFF point of the switch.

NOTE:

The use of an extension cord is not CSA

approved with this pump.

INSTALLATION

1. Install pump in sump pit with minimum diameter

of 10" (254mm). Sump depth should be 10”
(254mm). Construct sump pit of tile, concrete,
steel or plastic. Check local codes for approved
materials and for proper installation.

2. Install pump in pit so that switch operating

mechanism has maximum possible clearance.

3. Pump should not be installed on clay, earth or

sand surfaces. Clean sump pit of small stones
and gravel which could clog pump. Keep pump
inlet screen clear.

NOTICE:

Do not use ordinary pipe joint

compound on plastic pipe. Pipe joint compound
can attack plastics.

Risk of flooding. If the

flexible discharge hose is

used, make sure pump is secured in sump to
prevent movement. Failure to secure pump
may allow pump movement, switch
interference and prevent pump from starting or
stopping.

Summary of Contents for Easy Sump FPRP3250C

Page 1: ...65 6832 Fran ais Pages 8 12 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 365 6832 Espa ol Paginas 13 19 2010 FP884...

Page 2: ...ater alarm See the Troubleshooting Chart in this manual for information about common sump pump problems and remedies For more information see your retailer or call customer service at 1 800 365 6832 1...

Page 3: ...and tape it to the pump s discharge pipe Plug the pump and switch into a UL and or CSA approved type SJTW water resistant 3 prong grounding type extension cord The cord must be at least 14 AWG and no...

Page 4: ...mplete cycle For switch settings see the Electrical and Switch Specifications chart on Page 2 Failure to make this operational check may lead to improper operation premature failure and flooding OPERA...

Page 5: ...p operates but Low line voltage If voltage under recommended minimum check size of wiring delivers little or no water from main switch on property If OK contact power company or hydro authority Someth...

Page 6: ...ower Cord Assembly 1 PS117 54 TSU 2 Motor 1 3 Volute Upper 1 PS1 31P 4 Screw 8 32x5 8 Phillips Pan Head 4 5 Impeller 1 RP0000911A 6 Volute Lower 1 PS1 30P 7 Screw 8 16x1 2 Lg Pan Head 7 8 1 1 4 NPT x...

Page 7: ...C FP0FDC 1 3 HP Submersible Sump Pumps INTELLIPUMP Model FP0S1775A Pool Cover Pump Model FP0S1790PCA Utility Pump Model FP0S4100X 2 Years Condensate Pump Model FPCP 20ULST Back up Sump Pump System Mod...

Page 8: ...d eau Se reporter au Tableau de recherche des pannes de ce Manuel pour plus de renseignements concernant les probl mes courants des pompes de puisard et leurs rem des Pour de plus amples renseignemen...

Page 9: ...le tuyau sur l adaptateur et le fixer l aide d une bride de serrage 2 Soulever la rallonge et la fixer au tuyau de refoulement de la pompe l aide de ruban adh sif Brancher la pompe et l interrupteur d...

Page 10: ...sonn e dans la conduite de refoulement risque de geler et la pompe risque d tre endommag e 6 Apr s avoir install la tuyauterie le clapet antiretour et l interrupteur flotteur la pompe est pr te foncti...

Page 11: ...La cr pine d aspiration D poser la pompe et nettoyer la cr pine d aspiration ainsi est obstru e que l impulseur La pompe fonctionne Basse tension de la ligne Si la tension est au dessous du minimum re...

Page 12: ...oteur 1 3 Volute sup rieure 1 PS1 31P 4 Vis t te cylindrique empreinte cruciforme n 8 32 x 5 8 de pouce 4 5 Impulseur 1 RP0000911A 6 Volute inf rieure 1 PS1 30P 7 Vis t te cylindrique n 8 16 x 1 2 po...

Page 13: ...iscine mod le FP0S1790PCA Pompe usage g n ral mod le FP0S4100X 2 ans Pompe de r cup ration des eaux condens es mod le FPCP 20ULST Syst me de pompage de secours de puisard de soutien mod le FP2800DCC P...

Page 14: ...con CD y o una alarma de alto nivel de agua Consulte la Tabla de soluci n de problemas contenida en este manual para informaci n sobre problemas comunes de la bomba de sumidero y soluciones Para mayo...

Page 15: ...te el cord n y adhi ralo con cinta adhesiva a la tuber a de descarga de la Bomba Enchufe la bomba y con ctela a un cord n de alargue resistente al agua de tres puntas con puesta a tierra tipo SJTW apr...

Page 16: ...o No manipule la bomba o el motor de la bomba con las manos mojadas o cuando est parado en suelo h medo mojado o en el agua 1 La junta del eje depende del agua para su lubricaci n No haga funcionar la...

Page 17: ...movimiento del flotante Retire las obstrucciones est obstruido Tamiz de admisi n restringido Saque la bomba y limpie el tamiz de admisi n y el impulsor La bomba funciona pero El voltaje de l nea es b...

Page 18: ...luta superior 1 PS1 31P 4 Tornillo cabeza de cono achatado Phillips 8 32x5 8 4 5 Impulsor 1 RP0000911A 6 Voluta inferior 1 PS1 30P 7 Tornillo cabeza grande de cono achatado 8 16x1 2 7 8 Adaptador de 1...

Page 19: ...e agua en l nea 90 d as Bomba para todo uso Modelos FP0F360AC FP0FDC Bombas de sumidero sumergibles INTELLIPUMP de 1 3 HP Modelo FP0S1775A Bomba para cubiertas de piscina Modelo F0S1790PCA 2 a os Bomb...