DESCRIPTION

This Easy Sump™ is designed for home sumps. Unit is
equipped with a 3-prong grounding-type power cord.
Shaded-pole motor is oil filled and sealed for cooler
running. Sleeve bearings on motor shaft never need
lubrication. Automatic reset thermal protection. Not
designed for use as a swimming pool drainer.

SPECIFICATIONS

Power supply required ...........................115V, 60 HZ.
Liquid Temp. Range ................32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) ....15 Amps
Discharge:

Check Valve .......................1-1/4" slip / 1-1/2" slip
Hose ............................................................1-1/4"

NOTICE:

Do not reduce size of discharge pipe or

hose below 1-1/4” diameter. If discharge is too
small, pump will overheat and fail prematurely.

NOTICE:

This unit is not designed as a waterfall or

fountain pump, or for applications involving salt
water or brine! Use with waterfalls, fountains, salt
water or brine will void warranty.

Pump water only with this pump.

Do not use where water recirculates.
Not designed for use as a swimming pool drainer.

Risk of electrical shock. Do not

handle or plug in pump or pump motor with wet
hands or when standing on wet or damp surface or
in water. 

PERFORMANCE

ELECTRICAL & SWITCH SPECIFICATIONS

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give
many years of trouble-free service when correctly
installed, maintained, and used. However, unusual
circumstances (interruption of power to the pump,
dirt/debris in the sump, flooding that exceeds the
pump’s capacity, electrical or mechanical failure in
the pump, etc.) may prevent your pump from
functioning normally. To prevent possible water

damage due to flooding, consult your retailer about a
secondary AC sump pump, a DC backup sump
pump, and/or a high water alarm. See the
“Troubleshooting Chart” in this manual for
information about common sump pump problems
and remedies. For more information, see your
retailer or call customer service at 
1-800-365-6832.
1. Know the pump application, limitations, and

potential hazards.

2.

Do not use this pump in water with fish present. If
any oil leaks out of the motor it can kill fish.

3. Disconnect power before servicing.
4. Release all pressure within system before

servicing any component.

5. Drain all water from system before servicing.
6. Secure discharge line before starting pump. An

unsecured discharge line will whip, possibly
causing personal injury and/or property damage.

7. Check hoses for weak or worn condition before

each use, making certain that all connections are
secure.

8. Periodically inspect sump, pump and system

components. Keep free of debris and foreign
objects. Perform routine maintenance as
required. 

9. Provide means of pressure relief for pumps whose

discharge line can be shut-off or obstructed.

10. Personal Safety:

a. Do not plug in or otherwise handle with wet

hands or when standing on wet or damp
surface, or in water.

b. Wear safety glasses at all times when working

with pumps.

c. Keep work area clean, uncluttered and

properly lighted – replace all unused tools
and equipment.

d. Keep visitors at a safe distance from work

area.

e. Make workshop child-proof – with padlocks,

master switches, and by removing starter
keys.

11. When wiring an electrically driven pump, follow

all electrical and safety codes that apply.

12.

This equipment is only for use on 115 volt
(single phase) and is equipped with an
approved 3-conductor cord and 3-prong,
grounding-type plug.

TOTAL FEET (M) OF LIFT

5

10

15

Series

HP

(1.5m)

(3m)

(4.6m)

CAPACITY GALLONS(L)/HOUR

FPRP3250C

1/2

3200

2700

2000

24 Ft.

(12 113) (10 220)

(7 571)

(7.3M)

No flow 

at height

shown

below

Individual

Motor

Branch

*Switch Setting

Full Load

Circuit

in inches (mm)

Series

HP

Amps

Req.(Amps)

On

Off

FPRP3250C

1/2

5.5

15

8"(203)

3.5"(89)

Summary of Contents for Easy Sump FPRP3250C

Page 1: ...65 6832 Fran ais Pages 8 12 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 365 6832 Espa ol Paginas 13 19 2010 FP884...

Page 2: ...ater alarm See the Troubleshooting Chart in this manual for information about common sump pump problems and remedies For more information see your retailer or call customer service at 1 800 365 6832 1...

Page 3: ...and tape it to the pump s discharge pipe Plug the pump and switch into a UL and or CSA approved type SJTW water resistant 3 prong grounding type extension cord The cord must be at least 14 AWG and no...

Page 4: ...mplete cycle For switch settings see the Electrical and Switch Specifications chart on Page 2 Failure to make this operational check may lead to improper operation premature failure and flooding OPERA...

Page 5: ...p operates but Low line voltage If voltage under recommended minimum check size of wiring delivers little or no water from main switch on property If OK contact power company or hydro authority Someth...

Page 6: ...ower Cord Assembly 1 PS117 54 TSU 2 Motor 1 3 Volute Upper 1 PS1 31P 4 Screw 8 32x5 8 Phillips Pan Head 4 5 Impeller 1 RP0000911A 6 Volute Lower 1 PS1 30P 7 Screw 8 16x1 2 Lg Pan Head 7 8 1 1 4 NPT x...

Page 7: ...C FP0FDC 1 3 HP Submersible Sump Pumps INTELLIPUMP Model FP0S1775A Pool Cover Pump Model FP0S1790PCA Utility Pump Model FP0S4100X 2 Years Condensate Pump Model FPCP 20ULST Back up Sump Pump System Mod...

Page 8: ...d eau Se reporter au Tableau de recherche des pannes de ce Manuel pour plus de renseignements concernant les probl mes courants des pompes de puisard et leurs rem des Pour de plus amples renseignemen...

Page 9: ...le tuyau sur l adaptateur et le fixer l aide d une bride de serrage 2 Soulever la rallonge et la fixer au tuyau de refoulement de la pompe l aide de ruban adh sif Brancher la pompe et l interrupteur d...

Page 10: ...sonn e dans la conduite de refoulement risque de geler et la pompe risque d tre endommag e 6 Apr s avoir install la tuyauterie le clapet antiretour et l interrupteur flotteur la pompe est pr te foncti...

Page 11: ...La cr pine d aspiration D poser la pompe et nettoyer la cr pine d aspiration ainsi est obstru e que l impulseur La pompe fonctionne Basse tension de la ligne Si la tension est au dessous du minimum re...

Page 12: ...oteur 1 3 Volute sup rieure 1 PS1 31P 4 Vis t te cylindrique empreinte cruciforme n 8 32 x 5 8 de pouce 4 5 Impulseur 1 RP0000911A 6 Volute inf rieure 1 PS1 30P 7 Vis t te cylindrique n 8 16 x 1 2 po...

Page 13: ...iscine mod le FP0S1790PCA Pompe usage g n ral mod le FP0S4100X 2 ans Pompe de r cup ration des eaux condens es mod le FPCP 20ULST Syst me de pompage de secours de puisard de soutien mod le FP2800DCC P...

Page 14: ...con CD y o una alarma de alto nivel de agua Consulte la Tabla de soluci n de problemas contenida en este manual para informaci n sobre problemas comunes de la bomba de sumidero y soluciones Para mayo...

Page 15: ...te el cord n y adhi ralo con cinta adhesiva a la tuber a de descarga de la Bomba Enchufe la bomba y con ctela a un cord n de alargue resistente al agua de tres puntas con puesta a tierra tipo SJTW apr...

Page 16: ...o No manipule la bomba o el motor de la bomba con las manos mojadas o cuando est parado en suelo h medo mojado o en el agua 1 La junta del eje depende del agua para su lubricaci n No haga funcionar la...

Page 17: ...movimiento del flotante Retire las obstrucciones est obstruido Tamiz de admisi n restringido Saque la bomba y limpie el tamiz de admisi n y el impulsor La bomba funciona pero El voltaje de l nea es b...

Page 18: ...luta superior 1 PS1 31P 4 Tornillo cabeza de cono achatado Phillips 8 32x5 8 4 5 Impulsor 1 RP0000911A 6 Voluta inferior 1 PS1 30P 7 Tornillo cabeza grande de cono achatado 8 16x1 2 7 8 Adaptador de 1...

Page 19: ...e agua en l nea 90 d as Bomba para todo uso Modelos FP0F360AC FP0FDC Bombas de sumidero sumergibles INTELLIPUMP de 1 3 HP Modelo FP0S1775A Bomba para cubiertas de piscina Modelo F0S1790PCA 2 a os Bomb...

Page 20: ......

Reviews: