SYS11000OM Rev G
[UF 350-HD, Generic Template]
FLIR Systems Polytech AB
Page
36
of
70
Antennvägen 6
SE-187 66 Täby
Sweden
1.4.20
Laser Illuminator
Legend
FUNCTION
Description
Screen Symbology
Reference/Notes
(No legend)
Control type:
Three position
toggle switch with Safety Cover.
First arming is on Hand Controller.
Second arming is optional Key
Switch located in Aircraft.
Functions:
Multiple functions as
follows;
-
POWER OFF
1)
Power off, Release Fire Switch. Text field 18:
LI INOP
ARMING
2)
Close Safety Cover on HCU
and in Aircraft.
When aircraft is on ground (WoW)
the Laser Illuminator will be
automatically inhibited.
Text field 18:
LI INOP
READY
TO FIRE
3)
Ready To Fire:
a)
Select LP with Laser Sensor
Selecting Switch (1.4.18).
b)
Open Safety Cover on HCU
and move Switch to mid position.
c)
Set optional Key Switch to ON
position.
Laser Illuminator is now ready to
fire.
Text field 18:
LI INOP
Text field 18:
LI INH
Note: If Text field 18 =
LI INH
LOS is out of fire zone.
FIRE
4)
FIRE:
Push Switch on HCU.
In this position the switch is spring
biased (non-latching) On selection
of FIRE the Laser will illuminate
LOS target
Text field 18:
LI ON