SYS11000OM Rev G
[UF 350-HD, Generic Template]
FLIR Systems Polytech AB
Page
53
of
70
Antennvägen 6
SE-187 66 Täby
Sweden
1.10.2
BIT Codes
Code
Fault
Description
LRU
01
Azimuth TM Amplifier Disabled
Servo Loop Fault
TCU
02
Elevation TM Amplifier Disabled
Servo Loop Fault
TCU
03
Azimuth DM Amplifier Disabled
Servo Loop Fault
TCU
04
Elevation DM Amplifier Disabled
Servo Loop Fault
TCU
05
Scheduler Time Overflow
Processor Fault
TCU
06
INI File Read/Parse Fault
Processor Fault
TCU
07
Servo Amplifier Power Fault
Servo Loop Fault
TCU
08
RSPI Bus Master Fault
Internal Comms Fault
TCU
09
CCB temp sensor fault
Internal temperature
sensor Fault
TCU
10
CCB TEC overheat fault
High temperature in
system
TCU
13
Sensors fault
Sensors fault
TCU
15
Azm encoder init failed
Internal sensor Fault
TCU
16
Azm sin/cos signal fault
Internal sensor Fault
TCU
18
CDT: key values non-equidistant
Internal start-up Fault
TCU
19
CDT: minimum end key value too
close to low end limit
Internal start-up Fault
TCU
20
CDT: maximum end key value too
close to high end limit
Internal start-up Fault
TCU
21
CDT: maximum deviation limit
exceeded
Internal start-up Fault
TCU
22
CDT: too short calibration time
Internal start-up Fault
TCU
23
CDT: too long calibration time
Internal start-up Fault
TCU
24
CDT: incomplete calibration
(missing key values)
Internal start-up Fault
TCU