FLIR
LEPTON® Engineering Datasheet
The information contained herein does not contain technology as defined by the EAR, 15 CFR 772, is publicly available,
and therefore, not subject to EAR. NSR (6/14/2018).
Information on this page is subject to change without notice.
Lepton Engineering Datasheet, Document Number: 500-0659-00-09 Rev: 203
27
Telemetry
Row
Word
start
Word
End
Number
of 16-bit
Words
Name
Notes
C
11
11
1
Temperature
Gain Mode
Threshold Low to
High (K)
Temperature threshold in Kelvin used to
determine when an Auto switch to High gain
mode (while in Low gain mode) should occur in
TLinear mode
C
12
13
2
Reserved
C
14
14
1
Population Gain
Mode Threshold
High to Low
Population threshold in percent of the Gain Mode
ROI used to determine when an Auto switch to
Low gain mode (while in High gain mode) should
occur
C
15
15
1
Population Gain
Mode Threshold
Low to High
Population threshold in percent of the Gain Mode
ROI used to determine when an Auto switch to
High gain mode (while in Low gain mode) should
occur
C
16
21
6
Reserved
C
22
25
4
Gain Mode ROI (startRow, startCol, endRow, endCol)
C
26
47
22
Reserved
C
48
48
1
TLinear Enable
State
True if enabled
C
49
49
1
TLinear
Resolution
T-Linear resolution (0 = 0.1, 1 = 0.01)
C
50
50
1
Spotmeter Mean Spotmeter mean value in Kelvin within ROI
C
51
51
1
Spotmeter
Maximum
Spotmeter max value in Kelvin within ROI
C
52
52
1
Spotmeter
Minimum
Spotmeter min value in Kelvin within ROI
C
53
53
1
Spotmeter
Population
Number of pixel in Spotmeter ROI