427-0064-00-12 Version 100
August 2017
10
1
Camera Installation
1.4.1
Bench Testing
Note
Connect the power, Ethernet, and video, and confirm that the video can be displayed on a monitor
when the power is turned on. For configuration and basic setup information using the on-board web
server, refer to
Camera Bench Test, pg. 15
for specific details.
1.4.2
Analog Video Connections
The primary analog video connection of the camera is a BNC connector. The video cable used
should be rated as RG-59/U or better to ensure a quality video signal.
1.4.3
Connecting Power
The camera can be powered with a conventional 24 Vac or 12 Vdc
power supply, rather than PoE. Prior to making any connections,
ensure the power supply or circuit breaker is switched off.
The camera itself does not have an on/off switch. Generally the
FB-Series O camera may be connected to a circuit breaker and
the circuit breaker will be used to apply or remove power to the
camera. If power is supplied to it, the camera will be powered on
and operating.
Table 1-1: FB-Series O Camera Connections
Connection
Purpose
1
BNC
Analog video
2
Green barrel
not supported
3
Purple D-
not supported
Grey D+
4
Pink barrel
not supported
5
Ethernet
PoE power, communications, IP video stream
6
5-pin plug
not supported
7
2-pin plug
Vac or Vdc power
If the camera is to be mounted on a pole or tower or other hard-to-reach location, connect and
operate the camera as a bench test prior to mounting the camera in its final location.
Table 1-2: Power Connections
1
Vac or Vdc
(–)
2
Vac or Vdc
(+)
Figure 1-3: Power Connector
1
2