Should you encounter any problems, please feel free to email me at: [email protected]
14
An interface will appear by clicking the cross-shaped function key:
Input the following target values; 220 degrees for the extruder and 115 degrees for the heating
platform. After entering the values, the platform will start to warm up. When the extruder
temperature reaches 50 degrees, the cooling fan will activate and the current temperature value will
display to the right as shown below.
Feeding and withdrawing filament
To make the process of feeding or withdrawing the filament easy, please follow the next few steps
carefully: