This appliance should be connected directly to the fuse disconnect (or circuit breaker) through flexible, armored
or non-metallic sheathed copper cable. Allow some slack
in the cable so the appliance can be moved if servicing is ever necessary. A UL Listed strain relief or 1/2” (12.7
mm) conduit connector must be provided at each end of the power supply cable (at the appliance and at the
junction box).
When making the electrical connection, cut a 1 1/4” (32 mm) hole in the wall. A hole cut through wood must be
sanded until smooth. A hole through metal must have a grommet.
Suitable for use with solid state speed controls.
Downdraft Unit Internal Blower Electrical Connection
• Connect (L1/live) wire from the power supply cable into the right terminal Fig.19.
• Connect the green (ground) wire from the power supply cable into the middle terminal Fig.19.
• Connect the (neutral) wire from the power supply cable into the left terminal Fig.19.
• Ensure that the terminal screws are tightly holding all wires in place.
• Replace the cover of the terminal box Fig.18.
Fig.18