5. Install the Internal or Remote Blower
• For internal blower installation.
• For remote blower installation.
This downdraft unit may only be used in connection with DCS internal or remote blowers.
Internal Blower Installation in One of the Following Two Options:
Option 1: Internal blower, front installation for venting left, right or down
• Disconnect the cable from inside the downdraft unit. Plug in that same cable from the downdraft
unit into the internal blower Fig.7.
• Turn the venting collar on the internal blower box to the desired direction – left, right or down.
• Mount the internal blower box to the housing using four screws Fig.8.
• Continue to the ‘Prepare for electrical connection’ section.
Fig.7
Fig.8
Option 2: Internal blower, back installation for venting left, right or down
• The internal blower box can also be installed on the back of the downdraft unit to accommodate
the installation of a cooking range, range top or wall oven / cooktop in front of the downdraft unit.
• Remove the large cover on the back of the downdraft unit Fig.9.
• Turn the venting collar on the blower box to the desired direction - left, right or down. Disconnect
the cable from inside the downdraft unit. Plug in that same cable from the downdraft unit into the
internal blower and mount the blower box to the housing using four screws Fig.10.
• When finished, mount the previously removed cover onto the front of the downdraft unit Fig.11.
Updated: Fri, 28 Jun 2019 03:30:59 GMT