The Panda Generator
Seite/Page 56 - Kaptitel/Chapter 5: The Panda Generator
9.12.14
5.3.5 Components of Combustion Air
Stop Solenoid for Engine Stop
Some models are additional equipped with a
stop solenoid. The generator is stopped by the
co-operation of the stop solenoid immediately
after switching off. The adjustment of the stop
solenoid must always be checked, in order to
be sure that the stop lever operate freely and is
not placed under pre-stress.
Fig. 5.3.4-7: Stop Solenoid for Engine Stop
Air suction openings at the sound cover
The sound cover is provided at the upper sur-
face with drillings, through which the combu-
stion air can influx.
It must be consistently paid attention that the
generator is installed in such a way that from
no water can arrive into the proximity of these
air openings. (minimum distance 150 mm)
Fig. 5.3.5-1: Combustion Air Intake
Cooling air for coil cooling
The sound cover upper surface is provided at
back side with drillings, through which the coo-
ling air can influx.
It must be consistently paid attention that the
generator is installed in such a way that from
no water can arrive into the proximity of these
air openings.
Fig. 5.3.5-2: Freshwater Intake