The Panda Generator
9.12.14
Kapitel/Chapter 5: The Panda Generator - Seite/Page 55
Fuel Solenoid Valve
The fuel solenoid valve opens automatically if "START" is pressed on the remote control panel". The solenoid
closes, if the generator is switched to "OFF"position. It takes a few seconds before the generator stops. If the
generator does not start or does not run smoothly (i.e. stutters), or does not attain full speed, then the cause
is fore-mostly the solenoid.
Fig. 5.3.4-4: Fuel Solenoid Valve
Injection Nozzle
If the engine does not start after the
ventilation, the fuel injection lines must be
ventilated individually.
Fig. 5.3.4-5: Injection Nozzles
Glow Plugs
The glow plugs serve the pre-chamber for the
heating with cold start. The glow device must
be operated, if the temperature of the genera-
tor is below 16 ° C. This is practically the case
with each start. The glow device and starter
button are set so that neither may be used at
the same time.