![Fischer Panda Panda AGT 6000 Manual Download Page 139](http://html1.mh-extra.com/html/fischer-panda/panda-agt-6000/panda-agt-6000_manual_2294286139.webp)
Maintenance Instructions
9.12.14
Kapitel/Chapter 7: Maintenance Instructions - Seite/Page 139
Fig. 7.16.1-4: Impeller pump
Pull to the impeller with a multigrip pliers of the wave.
Mark the impeller, to make sure that these is used in the
correct position at re-installation.
Representative picture
Fig. 7.16.1-5: Impeller
Check to the impeller for damage and replace it if
necessary.
Before the reinsertion into the housing the impeller should
have been lubricated with glycerin or with a non-mineral oil
based lubricant e.g. silicone spray.
The impeller is attached to the pump wave (if the old impeller
is used, pay attention to the before attached marking).
Representative picture
Fig. 7.16.1-6: Gasket
Fastening the cover and use a new seal.