2 Way LCD remote paging

To page a 2 Way LCD remote just tap the ‘Red Circle’ twice.

Touch Panel Sensitivity

To change touch sensitivity open the driver’s door, hold the button on the back of the RPS Touch until the 
LEDs go out. Release button and tap again. The number of solid LEDs represent sensitivity of touch, 1 being 
the lowest, 5 the highest.

RPS Touch On or Off

You can turn the RPS Touch off from your remote. Just follow the instructions below:

STEP 1: 

Enter remote programming mode by holding down buttons 2+3 (Trunk and Key/Start buttons on 

2W901R-SS) simultaneously for 2.5 seconds. The remote will beep once and the LCD or read “REMOTE 
MENU” indicating that you have entered programming mode.

STEP 2:

 Scroll through the remote options by taping button 3 or 4 (Function button 2W901R-SS). Once the 

LCD RPS icon flashes reads “RPS-ON” tap button 1 or (Lock button 2W901R-SS) to turn this feature on. The 
LCD will read “RPS-OFF”

STEP 3: 

Exit remote programming by holding down buttons 2+3 (Trunk and Key/Start 2W901R-SS) 

buttons simultaneously for 2.5 seconds. The remote will beep indicating that you have successfully exited 
programming.

RPS (Remote Paging Sensor) Unlock/Disarm

RPS and car call functions do not require programming, however in order to unlock/disarm your vehicle you 
must program a 4 digit passcode (numbers 1 through 10 only) using the instructions below:

STEP 1:

 Disarm/unlock the alarm (remote must be programmed first) and choose a 4 digit code. You can 

not have zeros.

STEP 2:

 Turn ignition key to the “on” position and leave the driver’s door open.

STEP 3: 

Knock on the windshield in front of the RPS a total of 5 times (each time you knock the LED on the 

RPS will flash RED). The LED will begin to flash rapidly in BLUE with successful completion of this step.

STEP 4:

 Enter the first digit of the desired four digit pass code by knocking on the windshield in front of 

the RPS the desired number of times. For example, to enter 3, knock on the sensor 3 times (each time you 
knock the LED will flash RED) then wait.

CM6300

 

Install Guide

Alarm System

www.firstechonline.com | www.compustar.com

Copyright 2012 Firstech, LLC.

Page 8

   

 

Placement and Use of Components

                                     CM6300

Summary of Contents for CM6300

Page 1: ...lease visit www firstechonline com for additional installation resources MODEL RF 2W900FM 5PT Firstech LLC 21903 68th Ave S Kent WA 98032 Phone 888 820 3690 Fax 206 957 3330 Installation Manual CM6300...

Page 2: ...duction 4 Kit Contents 4 Installation Basics 5 Remote Programming Routine 6 Placement and Use of Components 6 Common Procedures 12 Wiring Descriptions 13 Option Programming Tables 20 Option Menu Descr...

Page 3: ...CM6300 Install Guide Alarm System www firstechonline com www compustar com Copyright 2012 Firstech LLC Page 3...

Page 4: ...T 6300A CONT controllers include the following CM6300 main control module Wiring diagram sheet Main wiring harness Wiring harnesses Hood pin Mountable bright blue LED Firstech dual stage shock sensor...

Page 5: ...s as well as the current ones Do not have antennas plugged into both ports on the CM6300 as the remotes will not function properly Supports Blade The CM6300 supports the Blade AL and TB systems as wel...

Page 6: ...ogramming Multiple Remotes After the confirmation flash given in STEP 2 code additional remotes by tapping Button I on two way remotes or the Lock button on one way remotes The parking lights will fla...

Page 7: ...gnition to the ON position and leave driver s door open STEP 3 Hold your finger over the Red Circle icon for 2 5 seconds STEP 4 When the siren chirps and LEDs flash in a circular pattern tap on your f...

Page 8: ...Trunk and Key Start 2W901R SS buttons simultaneously for 2 5 seconds The remote will beep indicating that you have successfully exited programming RPS Remote Paging Sensor Unlock Disarm RPS and car ca...

Page 9: ...ve times The Secure Valet Switch is more secure than traditional toggle valet switches because it requires a two digit code To program this feature you must perform the following procedures STEP 1 Tur...

Page 10: ...hrough 10 least sensitive This sets the impact sensitivity of Warn Away Zone 1 Setting Zone 1 will automatically set Zone 2 If you would like to manually set Zone 2 proceed To set Instant Trigger Zone...

Page 11: ...r the Authorized Tech section document titled FT EZGO Recommended Mounting Locations STEP 7 Program your EZ100 R and additional RF Kit remotes to the control module Maximum 3 Remotes including EZ100 R...

Page 12: ...ain outputs If these jumpers are used incorrectly damage to the vehicle and or control module may occur Jumper 1 Door Trigger Polarity Determines the polarity of the door trigger input wire red white...

Page 13: ...www firstechonline com www compustar com Copyright 2012 Firstech LLC Page 13 STEP 4 The control modules have a secure auxiliary option 4 05 This requires you to tap button 4 before you tap button 2 fo...

Page 14: ...ey in the off position 12V while the key is in the on position and 12V during crank This pin also has a thin green wire that is prewired to the starter kill relay If you are not installing starter kil...

Page 15: ...output to trigger sliding doors power windows or whatever other features you d like Pin 8 Violet Black Trunk negative input This is an optional input that will monitor when the vehicle s trunk has bee...

Page 16: ...llow Black Tach Sense input Connect this wire to a tach source for Ignition controlled door locks This is option 1 09 setting 3 The doors will lock once the rpms double from what they are programmed a...

Page 17: ...for trigger door lock systems For additional lock settings review Option Group 1 Pin 5 Blue Black Lock 250mA negative output This is an optional output that will provide a pulse for locking doors Sys...

Page 18: ...cables 4 to 4 or 4 to 6 Pin antenna cables do not work Do not use both Connector 9 and Connector 10 at the same time Connector 9 CN9 2 Pin Pre wired Thermister Plug optional thermister into this conn...

Page 19: ...Black Negative ground Pin 2 White 2nd stage negative input Instant trigger Pin 3 Red 12V positive output Pin 4 Yellow 1st stage negative input Warn away Connector 14 CN14 4 Pin Optional Sensor Input...

Page 20: ...ure Default Setting I Optional Setting II Optional Setting III Optional Setting IV 1 02 Lock Unlock pulse duration 0 8 sec 2 5 sec 0 125 sec 3 5 sec 1 03 Driver s priority unlock Off On 1 04 Double pu...

Page 21: ...g Input Key Sense Input Disable Arm Disarm when Brown White Wire Triggered Same Time 4 11 Bypass Through RS232 Port ADS Fortin 4 12 Impact Sensor Shock Sensor DAS Sensor 1st Stage Disarm Input 2nd Sta...

Page 22: ...again within 4 seconds the other doors will unlock The driver s door unlock must be isolated from the other doors and use the blue unlock The Orange Black CN4 will be used for your 2nd Unlock output t...

Page 23: ...re changes the behavior of the small orange white disarm wire When the feature is turned on it will change the default single pulse to double pulse upon disarm unlock 1 14 Auto Mode EZ GO This feature...

Page 24: ...grind circuit while the vehicle is remote started if the anti grind circuit is active and the start kill relay is installed in the ignition the relay will buzz while remote started 3 06 Factory Alarm...

Page 25: ...ation to be set for a specific length of time 1 99 sec only available when using the OP500 4 03 Aux 1 Output Control This feature allows the user to configure the method of which Auxiliary 1 can be ac...

Page 26: ...2 4 12 Impact Sensor This feature changes between the standard included shock sensor and the optional DAS Digital Adjustable Sensor The DAS has additional programming Please see the Placement and Use...

Page 27: ...you will need change special option 5 to number 10 This must be done with the OP500 Option Programming CM6300 Option Programming Using the OP500 programmer The OP500 can be used to program any availa...

Page 28: ...so read this section in its entirety before beginning IMPORTANT Special Option Groups cannot be programmed with a remote the OP500 must be used STEP 1 Select the option menu that contains the desired...

Page 29: ...for 2 5 seconds then Lock Key for 2 5 seconds Tap Key Button Tap Lock Button Tap Unlock Button Hold Trunk Button for 2 5 seconds Tap Key Button STEP 2 Scroll through menu allowing for 1 parking light...

Page 30: ...nds Tap Lock Button Tap Unlock Button Tap Key Button Hold Trunk Key for 2 5 seconds Option Menu 4 Lock Key for 2 5 seconds then Lock Key for 2 5 seconds Hold Trunk Key for 2 5 seconds Tap Lock Button...

Page 31: ...You no longer need to program the remotes before the OP500 will sync I need a ground when armed wire does the control module have one A You can use the ground when armed wire on CN3 that goes to the...

Page 32: ...the Ignition on and hold buttons 1 and 4 or Lock and Key Start for 2 5 seconds then the parking lights will flash 1 time on the CM6 series showing V 1 and so forth Current version 3 11 should show 3 f...

Reviews: