Connector 5 (CN5), 6-Pin
Pin 1 Not used
Pin 2 Violet/White - Trunk release 250mA negative (-) output. This is an optional output that will release
the trunk. Use CN1, Pin 2 if the vehicle is equipped with a (+) trunk release. System will unlock doors
and disarm alarm prior to trunk release.
Pin 3 Orange/Black - 2nd Unlock 250mA negative (-) output. This is an optional output that will provide a
(-) pulse for driver’s priority door lock. IMPORTANT: You must isolate the driver’s door and turn on
Option 1-3.
Pin 4 Blue - Unlock 250mA negative (-) output. This is an optional output that will provide a (-) pulse for
unlocking doors. System will unlock doors and disarm alarm. IMPORTANT: You must reverse polarity
for (+) trigger door lock systems. For additional lock settings review Option Group 1.
Pin 5 Blue/Black - Lock 250mA (-) negative output. This is an optional output that will provide a (-) pulse
for locking doors. System will lock doors and arm alarm. IMPORTANT: You must reverse polarity for
(+) trigger door lock systems. For additional lock settings review Option Group 1.
Pin 6 Not used
Connector 6 (CN6), 4-Pin (RS 232 Data Port)
This connector is used for updating control modules via www.compustar.com.
You must also use this port to
flash Blade bypass modules. This port provides simple connectivity of Fortin and iDataLink bypass modules.
This port is also used to communicate with DroneMobile controllers. Make sure to use the data port from
the DroneMobile unit to this RS232 port.
CM6300
Install Guide
Alarm System
www.firstechonline.com | www.compustar.com
Copyright 2012 Firstech, LLC.
Page 17