17 

1-13 

Pulse Trigger

 

– This option changes the amount of pulse trigger(s) needed to active the control 

module as a slave unit. The default setting requires two ground or 12V+ pulses to activate. 
Setting 2 changes the trigger to a triple ground or 12V+ pulse. Setting 3 changes the trigger to a 
single ground or 12V+ pulse to activate the remote start sequence. 

 
2-01 

Timer Start or Interval Between Cold Start

 - This option dictates the time interval when the 

control module will remote start. 

 

Default 1: 

Will start every 3 hours until the vehicle is remote started or started by key and run for 

the set run time in option 1-08. 

Option 2:

 Will start every 1.5 hours until the vehicle is remote started or started by key and run 

time in option 1-08.  

 
2-02 

Minimum Crank Time With Tachless Mode

 

– This option will increase the standard crank time 

from 0.8 seconds to 1.4 seconds when remote starting. Please keep in mind that the crank time 
will increase with each try.   

 
2-03 

Ignition Controlled Locks

 

– When you turn this option on and have the power door locks 

connected, the doors will lock when you remote start or start the vehicle with the key and then 
press the foot brake. When you turn the key off the doors will unlock if this feature is turned on. 
The feature also requires activation from the remote. Simultaneously tap the Lock + Remote Start 
buttons for a half second to activate ignition controlled door locks from the remote. The parking 
lights will flash once to indicate this feature is ON. 

 
2-04 

Engine Sensing

 

– This module comes default in Tachless mode where it does not require a tach 

connection. Setting 2 changes to the tach sensing where you will need to connect to a wire that 
tests as a tach. Setting 3 changes the mode to alternator sensing it does not require a tach 
connection. Setting 4 does an assumed start feature where the control module will automatically 
crank the yellow starter wire for 1.5 seconds. Please see 

the “Common Procedures” section on 

page 6-7 of this manual for complete explanations on the four engine sensing modes. 

 
2-05 

Minimum Crank Time With Alternator Sensing

 

– This option will increase the standard crank 

time from 0.8 seconds to 1.4 seconds when remote starting. Please keep in mind that the crank 
time will increase with each try.   

 
2-06 

Diesel Timer

 

– Use this option when installing on Diesel motors. You can use setting 2 and 3 for 

a default wait-to-crank; otherwise, you can adjust the time with your OP-500 Programmer. 

 
2-07  

Rearm Output

 - This option will change the behavior of the orange wire on CN2. This wire is 

used for triggering the factory alarm or shutting the RAP system off. 

 
2-08 

Siren Duration

 

– The default setting for the siren output upon panic or alarm trigger is 30 

seconds. You have the ability to extend that with this option. Please see the option tables for 
other available settings. 

 
2-09 

Siren Output

 

– The brown wire on CN3 can be changed to output a pulsed (+) 12V output. 

 
2-10 

Horn Output

 

– This option sets the behavior of the horn wire during alarm state, during double 

lock from the remote or during lock and unlock from the remote. During one of the options the 
event will send a negative pulse on the white wire on CN2. 

 

 

2-11 

Horn Honk

 

– This option sets the duration of the output on the horn (white) wire. At default it will 

pulse depending on option 2-10. At the optional setting it will latch a ground trigger to use for 
triggering another siren.

 

Summary of Contents for CM600-AS

Page 1: ...eceived including interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to ope...

Page 2: ...n Harness 11 Connector 3 CN3 8 Pin Harness 11 Connector 4 CN4 6 Pin Lock Harness 12 Connector 5 CN5 4 Pin RS232 Port 2 Way Data 13 Connector 6 CN6 4 Pin Antenna Cable 13 Connector 7 CN7 2 Pin Pre wire...

Page 3: ...n Call 888 820 3690 or visit our website at www compustar com to locate your nearest dealer Caution The Manufacturer s warranty will be void if this product is installed by anyone other than an author...

Page 4: ...arn Tach STEP 1 Start the vehicle with the key and allow it to idle down STEP 2 Press and hold the foot brake STEP 3 While holding the foot brake hold the remote start button on the remote for 2 5 sec...

Page 5: ...each additional remote The CM600 AS can store up to three remotes Exiting Programming Programming is a timed sequence If you can not get the remote s to program then the system enters Valet Mode The...

Page 6: ...twice to confirm the system is out of Valet Mode 2 You can put the system into Valet by holding the foot brake and then turning the ignition key on and then off five times within 7 seconds The parking...

Page 7: ...l for 2 5 seconds The parking lights will flash once to confirm a good tach signal The parking lights will flash three times to indicate the tach did not learn Two seconds following the three flashes...

Page 8: ...ng section of this manual for details Upon receiving confirmation that your vehicle is running the parking lights will light solid The remote start run time can be set for 3 15 25 or 45 minutes The op...

Page 9: ...9 CM600 AS Wiring Schematic...

Page 10: ...ry Pin 6 Yellow Starter 12V positive output This wire must be connected for remote start The proper wire will test 0V with the key in the off position 0V while the key is in the on position and 12V du...

Page 11: ...l pulse the factory horn The proper wire will show ground while the horn is sounding Pin 8 Gray Black Instant negative trigger input This input looks for a ground input when the system is armed locked...

Page 12: ...ng doors or power windows The settings can be changed via option 3 02 To set a custom timed output you must use option setting 4 as well as an OP500 Option Programmer Pin 8 Yellow White Auxiliary 2 Ou...

Page 13: ...he signal from remote Pin 2 White TX output This wire transmits the signal to remote Pin 3 Red Constant 12V positive output Pin 4 Black Negative ground Connector 7 CN7 2 Pin Pre wired LED Pin 1 Black...

Page 14: ...Only Aux 3 1 12 Dome Light Delay Off 5 Seconds 45 Seconds Auto 1 13 Trigger Start Triple Pulse Double Pulse Single Pulse Feature Default Setting I Optional Setting II Optional Setting III Optional Se...

Page 15: ...e Prewarn 2nd Stage Instant 1st Stage Disable Arm Disarm 2nd Stage Instant 1st Stage Input Prewarn 2nd Stage Disable Arm Disarm 3 09 Sliding Door Aux 1 Aux 2 Control for iDatalink Modules Off Unlock F...

Page 16: ...Disarm Wire This feature turn the disarm wire into a double pulse output for shutting down factory alarm outputs 1 06 IGN ACC Pulse with Disarm This option will pulse the ignition and accessory wires...

Page 17: ...Setting 2 changes to the tach sensing where you will need to connect to a wire that tests as a tach Setting 3 changes the mode to alternator sensing it does not require a tach connection Setting 4 doe...

Page 18: ...wire on CN3 Default 1 Will pre warn with a negative ground input Option 2 Will arm the system with a negative ground input Used when adding an alarm to a factory keyless entry system Option 3 Turns t...

Page 19: ...nected the OP500 will power up as long as the main ignition harness to the controller has been connected properly STEP 3 To change the option number you wish to program use the left and right arrow ke...

Page 20: ...3 Lock Key Start for 2 5 seconds then Lock Unlock for 2 5 seconds Option Menu 4 Lock Key Start for 2 5 seconds then Lock Key Start for 2 5 seconds STEP 3 Once the system confirms the option number set...

Page 21: ...tach before 1st remote start 2 Ignition on or foot brake on 5 Foot brake on 6 Hood open 8 Remote start failure 10 System is in Valet Mode Alarm LED Diagnostics When the alarm is triggered the LED if...