4 0
Optional Equipment
(for qualified installers only)
Travis Industries
9 3 5 0 8 1 1 6
0 3 1 0 0 0
4
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice. The
propane conversion kit includes pilot orifice with "35" stamped on it. Replace burner pan.
Lift the pilot hood
off the pilot
assembly.
5/32" Hex
Use a hex wrench to
unscrew the orifice.
Remove the orifice and replace with the LP orifice. Screw the
orifice all the way in and replace the pilot hood.
LP (Propane) Orifice
Orifice Identification:
NG (Natural Gas) Orifice
35
62
35
a
b
c
NOTE: when re-attaching,
this pin lines up with the
notch in the pilot hood.
5
Remove the regulator
from the front of the
gas control valve.
Replace with the
propane regulator,
using the new gasket
and screws included
with the regulator.
NOTE: Leak test
this area after the
heater is installed,
gas is connected,
and the main
burner is lit.
NOTE: this illustration shows the gas control valve
with the inlet to the left. On the FPX 35 CB the valve
will be rotated 180°.
Place the LP
label on the base
of the fireplace
near the gas
control valve.
d
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
Remove and discard the
regulator, diaphram, spring
and center post.
a
b
Slotted
Screwdriver
(or T-20 Torx)
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
c
Slotted
Screwdriver
(or T-20 Torx)