14
Installation
(for qualified installers only)
Travis Industries
9 3 5 0 8 1 1 6
0 3 1 0 0 0
Face Installation & Sizing - 36 DV Faces
(requires part # 98500536)
1/4" Nutdriver
Right Side Face
Mounting Bracket
Left Side Face
Mounting Bracket
With the fireplace in place and glass removed, install the tile stop for the type of
face used (see illustration to the right) - included with kit # 98500536.
Install the face mounting brackets (included with kit # 98500536).
Install the tile (or other non-combustible facin). Make sure tile does not interfere
with the press-nuts on back of the mounting brackets (see page 12).
Slide the mounting brackets all the way back against the facing.
Install the face using the instructions included with the face, disregarding any
bracket instructions. Refer to the illustration of the bracket (below right) to
determine the correct hole or slot for attaching the face to the brackets.
Steps for installing 36 DV Faces
a)
b)
c)
d)
e)
Rectangular
Bevel Faces
Classic Arched
Faces (except
artisan)
Architectural
Faces
Artisan Faces
These holes in the mounting brackets are
slotted to allow for different thicknesses of tile
(or other non-combustible facing).
Detail of Mounting Bracket
Tile Stop for
Arched Faces
Tile Stop for Rectangular
and Architectural Faces
The tile stops
attach to
these holes
Arched Faces
Attach the center bracket through
the key-hole slots.
Tighten the nuts
on the bracket to
secure.
3/8" Wrench
Rectangular Bevel Face
(Black or Gold)
Access Door
38”
27-1/2”
Classic Arched
(Gold, Black, or Artisan*)
29"
5"
36”
Access Door
Radius = 35”
* Artisan faces may vary slightly in size
due to the forging process.
29-3/8”
36-1/4”
Access Door
Architectural Faces
(French Country,
Arts & Crafts,
Art Deco, or Neo-Classical)