Fireline FPW Owner'S Manual Download Page 30

 

 

 

30 

LT6498 (ISS 2) 

GAS FIRE COMMISSIONING CHECKLIST 

This Commissioning Checklist is to be completed in full by the competent person who commissioned the gas fire as a means of 
demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future 
reference. 

Failure to install and commission according to the manufacturer’s instructions and complete this Benchmark Commissioning Checklist will 
invalidate the  warranty. This does not affect 

the customer’s statutory rights.

 

*All installations in England and Wales must be notified to be Local Authority Building Control (LABC) either directly or through a 
Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer. 

Site  Requirements 

Yes 

N/A 

Was the chimney checked to ensure it only serves one flue/fire, has no obstructions and is continuous? 

 

 

Has any debris at the base of the chimney been removed? 

 

 

For brick chimney installations is there enough depth for 12 litres of debris, or precast flues 2 litres of debris? (see instructions for 
debris gap details) 

 

 

Have damper and register plates been removed or locked in the fully open position ensuring correct size of flue is maintained? 

 

 

If previously used for solid fuel has the chimney been thoroughly swept? 

 

 

If the chimney is pre-cast has the inside of the flue been checked for extruded cement / sealant which must be removed? 

 

 

Has the fire place been checked for under-floor air supply which must be sealed off? 

 

 

Has the chimney been inspected prior to fitting the gas fire to ensure that it is in good condition? 

 

 

Has the structure of the chimney been checked for leakage using a smoke pellet test? (See BS5440-1 for details). 

 

 

Ventilation 

Does the installation require any additional ventilation requirements as detailed in the manufacturer’s instructions? 

 

 

Hearth Requirements- where fitted 

Is the hearth constructed from non -combustible material? 

 

 

Is the hearth a minimum of 12mm thick with a minimum 

floor to top surface of 50mm?(BS5871) or as per manufacturer’s 

instructions? 

 

 

Is the hearth for open fronted fires a minimum of 760mm wide and has 300mm projecting from the fire opening 
(BS6871) or to manufacturer’s instructions? 

 

 

Mounting height (where applicable) has the fire been installed to the correct mounting height- 

as per manufacturer’s instructions? 

 

 

 

Firebox and Fuel Bed 

Has the fuel 

bed, coals, pebbles etc. been fitted to manufacturer’s instructions? 

 

 

Gas Supply 

Has an isolation tap/restrictor inlet elbow been fitted for servicing? 

Has the gas supply been thoroughly purged prior to connection to remove any debris? 

 

 

Has a gas tightness test been completed prior to breaking into the gas supply and following completion of 
installation?(IGEM/UP/1B) 

 

 

Record burner gas pressure reading? If only the supply pressure is available a gas rate must be undertaken.(GSIUR REG26/9C) 

 

 

Record dynamic inlet gas pressure (working pressure) reading (all gas appliances running) 

 

 

Spillage test 

Installation passes smoke match test with any extractor fans turned on (see manufacturer’s instructions) 

 

 

Installation 

Has the gas fire been installed a

nd commissioned in accordance with manufacturer’s instructions? 

 

 

Has the fire been installed with the correct clearance to combustible materials, as per manufacturer’s instructions? 

 

 

The operation of the appliance and controls have been demonstrated to the customer including battery replacement where 
applicable? 

 

 

The manufacturer’s literature, including Benchmark Checklist and Service record has been explained and left with the customer? 

 

 

Has the appliance been registered with the Local Authority as detailed on the Gas Safe web site and is a legal requirement and 
forms part of the warranty? 

 

 

Customer’s Signature: 

Commissioning Engineer’s Signature: 

(To 

confirm satisfactory demonstration and receipt of manufacturer’s literature) 

Summary of Contents for FPW

Page 1: ...tforservicelogandfuturereference For use in Great Britain and Ireland Literature NO 6498 ISS 2 IMPORTANT This appliance is guaranteed for 12 months subject to conditions The 5 year extended parts warranty will only be valid if the annual service recommended in this manual has been completed and appliance has been registered online ...

Page 2: ... on the opposite page and ensure your installer has filled in the appropriate checklist This in no way reduces your statutory rights Your warranty commences from the date of purchase and you must retain your receipt or invoice as proof of a purchase date THIS EXTENDED WARRANTY SPECIFICALLY EXCLUDES GLASS AND SOFT REFRACTORY COMPONENTS THE BULB AND ANY BATTERIES Terms and Conditions 1 The appliance...

Page 3: ...lations England and Wales All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme A Building Regulations Compliance Certificate will then be issued to the customer who should on receipt write the Notification Number on the Benchmark Checklist This product should be serviced regularly to optimise its safety efficiency and performance T...

Page 4: ...g Installer information required to register for the extended warranty Name Date of installation Gas safe number Important For future reference we suggest you record the following details here and keep the receipt as proof of purchase This information may be asked for when you contact the helpdesk MODEL FXW FPW FREESTANDING GAS STOVE Serial No This information can be found on the label attached to...

Page 5: ... Logs or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped in polythene and be clearly labelled RCF waste These materials are not classified as hazardous waste and should be disposed of at a site licensed for the disposal of industrial...

Page 6: ...earance of the appliance However if excessive black staining does occur it may be due to the fuel bed being incorrectly laid This should be checked prior to contacting a service engineer Care must be taken to prevent any damage being caused to surrounding soft furnishing or decoration e g many embossed vinyl wall coverings may become discoloured if placed too close to the appliance Combustible mat...

Page 7: ...t is possible to adjust the height of the flames by turning the control knob between the positions marked and Note that the knob latches in position at either end of this movement and must be pushed in slightly before it can be turned 6 To turn the fire off depress the knob slightly and turn it to the position 7 To completely extinguish the fire depress the knob slightly and turn to the position I...

Page 8: ...ke care when cleaning in this area so as not to damage the pilot assembly Glass Cleaning From time to time it will be necessary to clean the glass panel of your Fireline FXW FPW Gas Stove We recommend you use a Ceramic hob cleaner these are available for all leading super markets i e ASDA TESCO SAINSBURY S Etc Brands of hob cleaning we have tested and found suitable are HOB BRITE VITRO CLEN Ensure...

Page 9: ...t the appliance is turned off and cold Use only the fuel bed components provided and no additional parts must added Incorrect positioning of the fuel bed components could result in the staining of the glass panel Important Refer to the Health Safety Notice located on page 5 of this booklet before cleaning or replacing any refractory material The fuel bed components are delicate and they should be ...

Page 10: ...thin layer of vermiculite over the stainless steel burner making sure not to cover or block the pilot assembly on the left hand side Before laying the rear shapes make sure that the cut out s in the shapes are at the rear as shown in the picture ...

Page 11: ...ck and the Bark effect at the Top so they lie on the pointed edge Position the shapes so the bottom V of the shapes are between the first row of Air Holes and the second row of Air holes behind the burner bar Place a single layer of Bark Chips in front of the Burner Bar making sure not to cover or obstruct the Pilot assembly or rest too far onto the Burner Bar ...

Page 12: ...sible resting on the rear shape and resting on top of the Bark Chips as shown in the picture Place the second Log Shape 4 next to the first shape so it touches at the front right hand side and leaves a gap between the first shape at the rear Make sure not to disturb the Bark Chips ...

Page 13: ...pes as shown Place the last Log Shape 6 as so that is as far back and to the left as possible at the rear and as far to the right at the front so it touches the third log shape Make sure all the shapes are touching at the front and that they are evenly spaced at the rear as shown in the picture this will produce the best flame picture ...

Page 14: ...g this is quite normal and does not affect the operation of the appliance It is advised that a competent person service the Fireline FXW FPW fire annually The fire is more likely to provide trouble free operation Dulling and slight discoloration inside the firebox will occur adding to the realism of the appliance This is normal It is important that The chimney or flue is checked annually to ensure...

Page 15: ...r 1 0mbar Pressure Test Point Location Gas inlet elbow Gas Input 5 5 kW Gross Max 5 0kW Gross Max 2 4 kW Gross Min 2 4kW Gross Min Injectors Mk 360 Mk 116 Oxy pilot 9044 N G 2550 N G 9222 L P G Gas Connection 8mm compression semi rigid or rigid Data Badge located on inside of door or on plate attached to the rear of stove Appliance Dimensions FXW FPW STOVE DIMENTIONS STOVE SHOWN AS TOP EXIT ...

Page 16: ...as been used for this efficiency calculation GasTec have certified the test data from which it has been calculated The efficiency value may be used in the UK Government s Standard Assessment Procedure SAP for energy rating of dwellings When unpacking the appliance please check the following items are included Fuel Bed 6 piece Log fuel bed Vermiculite Bark Chips Closure Plate Owners Manual Fixing K...

Page 17: ...e following British Standards Failure to do so could lead to prosecution The following are relevant codes of practice and British Standards B S 5871 B S 5440 PART 1 PART 2 B S 6891 This appliance must be installed to current versions of the above standards and include any relevant amendments to The Building Regulations Issued By The Department Of The Environment The Building Standards Scotland Con...

Page 18: ...ay be evident This is the starch binder used during the manufacture of the fibre components of the fire and there are no harmful effects produced Care must be taken to prevent any damage being caused to surrounding soft furnishing or decoration e g many embossed vinyl wall coverings may become discoloured if placed too close to the appliance Note Dampers or register plates must not restrict any of...

Page 19: ... minimum clearance of 50mm between its open end and the nearest obstruction The Flue Pipe must be 125mm 5ins minimum diameter can be lengthened by a maximum of 150mm 6ins between the Elbow and Closure Plate REAR EXIT Using Elbow Spigot and a 90 degree Bend The Stove can be fitted by using the Elbow Spigot provided attached horizontally on the Stove and connected to a 90 degree elbow so that the fl...

Page 20: ...mber not surface finishes is approximately 80 85 degrees C with a normal ambient room temperature Temperatures of combustible materials can be substantially lowered with a simple heat shield constructed of a non combustible material and small air gap between the shield and combustible material Clearance to Shelf Minimum clearance from hearth to underside of combustible shelf should be 740mm provid...

Page 21: ...ould be made to the siting of the appliance as a spillage test will need to be carried out at the Draught Diverter at the rear of the stove When siting into an Inglenook consideration should be made for access to the rear of the appliance either from to top or sides of the stove so a spillage test can be witnessed A small mirror may be required A minimum of 45mm needs to left between the rear of t...

Page 22: ...n established If all the smoke is not drawn into the flue pre heat the flue with a blowtorch or similar and re check If there is any uncertainty examine for the cause and if necessary seek expert advice No combustible material should be fitted inside the fireplace opening GAS SUPPLY ROUTING Use rigid or semi rigid tube to connect the supply Determine the gas supply pipe route to the appliance befo...

Page 23: ...supply at the external Isolation valve Remove the pressure test point screw from the inlet elbow and connect the pressure gauge Turn on the gas to the appliance at the Isolation valve Rotating the control to the ignition position and push in to allow the air in the pipe to be purged Rotating the control knob a few times check that the electrode is sparking at the gap between the thermocouple tip a...

Page 24: ...re starting from cold Light the fire and leave at maximum input Close all the doors and windows After five minutes fit the smoke match in a holder and position as illustrated with the head of the match just inside the test opening Run the match along the bottom edge of the Draught Diverter All smoke must be drawn into the test opening if the clearance is satisfactory If spillage occurs wait a furt...

Page 25: ... and correct operation of the appliance Before commencing any service or replacement of parts turn off the gas supply to the fire After servicing check for gas soundness When ordering spare parts please quote appliance name and serial number these can be found on the data badge which is located on the left hand side of the appliance behind the trim or fascia At least once a years check for debris ...

Page 26: ...n the supply pipe Unscrew the locking nut holding the injector on the chassis Clean or replace the injector NOTE Do not use a wire or a drill to clean out holes Injectors are different sizes Refer to the appliance data section for details Re assemble in reverse order REPLACEMENT OF OXY PILOT ASSEMBLY NOTE If the pilot assembly is replaced it must be replaced by an identical unit from the same manu...

Page 27: ... instructions SECTION TWELVE Short Spare s List Parts may vary change due to development of products A serial number should always be supplied when ordering parts to make sure you receive the correct part Parts able to be ordered by customer Part Description Part Number Log set 6394 Pilot Shield 7195 Cool touch handle 7028 Parts that require a GAS SAFE engineer to order fit Part Description Part N...

Page 28: ...28 LT6498 ISS 2 ...

Page 29: ...www charltonandjenrick co uk 29 LT6498 ISS 2 Register your appliance online today to active your warranty ...

Page 30: ...facturer s instructions Hearth Requirements where fitted Is the hearth constructed from non combustible material Is the hearth a minimum of 12mm thick with a minimum floor to top surface of 50mm BS5871 or as per manufacturer s instructions Is the hearth for open fronted fires a minimum of 760mm wide and has 300mm projecting from the fire opening BS6871 or to manufacturer s instructions Mounting he...

Page 31: ...ays use the manufacturer s specified spare part when replacing controls SERVICE 01 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 02 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 03 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 04 Date Engineer name Company na...

Page 32: ...Assembly Restrictor Elbow 2189 Log Fuel Bed 6394 Bag of Vermiculite Bag of Bark Chips Glass Panel Closure Plate Fixing Kit 3xAllen keys stand off brkt bolts Data Badge Warning Label ID Label Packing Labels Owners Book Bottle Of Black Paint Handle Semi Circle Restrictor Plate Spigot Gasket Flue Spigot Button Magnets x 4 Part No 4159 Serial Number Inspector ...