24
LT6498 (ISS 2)
Lay Log fuel bed as described under Users Section.
Warning:
It is important that the fuel bed components are positioned as shown in these instructions.
If the fuel bed components are not positioned correctly this may result in damage to the glass.
DOOR CLOSURE AND SECURING OF THE DOOR:-
Close the door at the handle making sure that the seal is correctly positioned to make a good tight seal and
refit the Allen screw to the side of stove. This is for safety reasons so the Door cannot accidently opened by
knocks to the handle.
CHECKING FOR COMBUSTION PRODUCTS CLEARENCE
IMPORTANT:-The smoke test must be
carried out with the fire starting from cold.
Light the fire and leave at
maximum input.
Close all the doors and windows.
After five minutes fit the smoke
match in a holder and position as
illustrated with the head of the
match just inside the test opening.
Run the match along the bottom
edge of the Draught Diverter All
smoke must be drawn into the test
opening if the clearance is
satisfactory.
If spillage occurs wait a further five
minutes and repeat the test.
Repeat the test with doors open
and with any extractor fans in
other rooms in operation.
If spillage is detected the cause
must be discovered and the fault
corrected, if the fault cannot be corrected, disconnect the fire from the gas supply and seek expert advice.
Spillage can be caused by a restriction in the flue system, down draught or insufficient ventilation into the
room where the fire is installed.