18
LT6498 (ISS 2)
IMPORTANT NOTE: -
WARNINGS
The glass front of the fire act as a dress guard, conforming to BS 1945 (1971) and satisfies the heating appliance
regulations (1991) However, a guard conforming to BS6539 (1984) must be used to protect young children, the
elderly or infirm.
This appliance incorporates a safety device in the form of an Oxygen depletion system. IT MUST NOT BE
ADJUSTED OR PUT OUT OF OPERATION! THIS IS A NON-SERVICABLE ITEM AND MUST BE EXCHANGED AS A
COMPLETE ASSEMBLY; USING ONLY THE ORIGINAL MANUFACTURER'S PART.
A non-combustible hearth must be provided to comply with the building regulations, or a suitable proprietary fire
surround with a 150°C minimum rating.
During initial firing, an odour may be evident. This is the starch binder used during the manufacture of the fibre
components of the fire, and there are no harmful effects produced.
Care must be taken to prevent any damage being caused to surrounding soft furnishing or decoration; e.g. many
embossed vinyl wall coverings may become discoloured if placed too close to the appliance.
Note: Dampers or register plates must not restrict any of the above flues. The flue must only service a
single appliance and not have any branches or traps, which may impede the natural draught. If a terminal
is fitted it must be suitable for the purpose.
Note: A non combustible hearth must be provided beneath the appliance and must extend outwards all around the
appliance base. The hearth must be level and have a minimum thickness of 12mm and must have a clearly defined
edge (change of level) to discourage placing of any combustible materials on or partially over it.
Summary of Contents for FPW
Page 28: ...28 LT6498 ISS 2 ...