IMPORTANT:
It is permissible to reverse the burner pan in the field to enable a closer gas line connection if necessary.
BURNERPAN REMOVAL
The burnerpan is secured in the fireplace with two screws. They are located at the outer edge of the burnerpan on each
corner (See Fig. 2). Remove both screws and lift the burnerpan out of the firebox for gas connection.
Inlet Gas Supply
Gas Shut-Off
Firebox Area
Valve Box
GAS LINE:
The gas line must have a predetermined location to enable it to be installed. Fig. 1 shows one example of an
inlet gas line with a gas shut off at the fireplace. This allows a technician to shut the inlet gas supply OFF and remove the
burner for servicing.
It is imperative that the flex line from the gas shut-off be long enough to lift out burner pan
for service.
Ensure you follow the local and state gas codes per your installation.
RECOMMENDATION:
Once the gas line is established it is recommended to remove the burner pan from the firebox
until the fireplace is in the final stages and ready for the burner installation. See Burnerpan Removal below.
INSTALLATION PRECAUTIONS
FRAMING:
After framing is complete, slide the fireplace into position and secure it with the side nailing flanges. Next
install cement board, securing it to the metal studs and fireplace. The framing provides for a flush fit up to the opening of
the fireplace.
DO NOT PROTRUDE INTO THE FIREPLACE OPENING WITH CEMENT BOARD.
Fig.1
Close up view of inlet gas connection with
shut-off valve.
VENTILATION FOR NON-COMBUSTIBLE ENCLOSURE
Fireplaces are subjected to many outdoor elements such as
rain, snow, wind, heat or cold.
A minimum of 18 square
inches of cross ventilation (2 sides) is required to keep
the components in good working order.
Use Fig. 3 as a
guide.
Fig 3.
Cross ventilation example providing minimum of 18-square
inches per side using Firegear VENT-KIT-6x12 provided.
REV. 1-5-17 Page 5
Kalea Bay Outdoor Fireplace
CAUTION:
BEFORE BEGINNING INSTALLATION CAREFULLY REMOVE THE
GLASS WINDSHIELDS, PARTS BOX AND ANY PACKING MATERIALS FROM
FIREPLACE AND SET ASIDE FOR LATER USE.
Bu
rn
er
Fireplace Side Wall
Pilot C
over
Remove Screw
Bu
rn
er
pa
n
Fig. 2
Removal of burnerpan screws.
Summary of Contents for OFP-L36TFS-N