![Fiori BATCH CONTROLLER Use And Maintenance Manual Download Page 73](http://html.mh-extra.com/html/fiori/batch-controller/batch-controller_use-and-maintenance-manual_2290575073.webp)
73
REV. 00 02/01/2015
id.:
ALARM LIST
5
5.1
OPERATING ALARMS
These alarms are displayed in a yellow box on the active page.
They may be generated during the components loading operations.
MACHINE TILTED TOO MUCH
excessive tilting of the machine along the front axis
CORRECT THE INCLINATION
correct the front tilting of the machine
LOWER BOOM AND REPEAT
slowly lower the boom and repeat the operation
WEIGHING ERROR
weighing error
EXCESSIVE VIBRATION
the system has detected an excessive weight vibration during weighing
LOWER BOOM AND REPEAT
slowly lower the boom and repeat the operation
WEIGHING ERROR
generic weighing error
LOWER BOOM AND REPEAT
slowly lower the boom and repeat the operation
NON EMPTY BUCKET
the load has not been poured completely into the drum
FULL DISCHARGE BUCKET IN DRUM Lift the boom back up again and pour the load in the drum
ESC TO ABORT
press ESC to cancel the error
EXCESSIVE LOAD
the total load of the component exceeds the preset value
5.2
SYSTEM DIAGNOSTICS ALARMS
alarm messages related to the peripheral devices
These alarm messages are signalled by a triangle on the up right corner of the screen and are
accompanied by an acoustic signal.
progressive number (1 of / ....)
alarm code
(refer to alarm
table)
description
solution