MODE FUNCTIONS FOR THE FOREMAN ONLY
4
4.3
COMPONENTS AND RECIPES
To set or modify the list of components to be used in the recipe.
Some components are preset by the manufacturer, however all components may be set or modifi ed.
Up to 32 components may be set
In the main page (used by the opera-
tor) only the components with weight
different from zero will be displayed .
The fi rst component must always be WATER
component type:
Water = water,
---- = generic
progressive index
component name
value (kg) to be loaded to run the
recipe)
To write or change the name of a component
- Use the arrow
keys to select the component
- Press
C
several times to delete the name and then write it again.
- Press OK
to confi rm
To change the preset value
- Select the value you want to change
- Enter the new value
- Press OK
to confi rm
- Press ESC