8
ATTACHMENTS
1. Extension hoses for reaching remote areas are available in 50 ft. (15 m), 100 ft. (30m),
and 200 ft. (60m) lengths. All connections are camlock quick-operating fittings. The
hose is connected to the end of the discharge boom in place of a nozzle. The nozzle is
connected to the end of the hose and controlled by the person on the ground. The flow is
controlled by a second person on the HydroSeeder
®
. This allows for a full pressure and
volume operation.
Since the extension hose is pressurized with the full output of the
pump with the recirculation closed, the equipment operator and
individual at the end of the hose should exercise extreme care when operating the unit at
high pressure. The high pressure on the hose can exert strong forces, causing the potential
for the hose operator to lose control of hose or footing. The hose will require additional hose
holders when operation occurs on slopes. Engage (turn on) pump clutch only after the hose
operator is fi rmly positioned and has fi rm control of hose. Failure to comply could result in
minor personal injury or product or property damage.
2. For lower pressure applications, or for close-up work, such as around buildings, the
remote valve attachment can be used. The attachment includes a semi-rigid hose with
quick-disconnect fittings along with a hand-held valve that fits the end of the hose and
accepts the standard nozzle assemblies. The hose is connected to the outlet on the
discharge pipe above the pump. The machine is run at 1/2 to 3/4 throttle to apply material
where desired.
The recirculation valve must be open when using a remote valve.
Failure to comply WILL result in severe personal injury or death.
3. Hose Reel: The live hose reel will mount on the HydroSeeder
®
or on the truck frame. The
200 ft. (61 m) capacity hydraulic rewind reel will wind up and store empty hose. A pivoting
feature provides three locking positions, enabling curb-side, 45 degree, and rear-hose
discharge. The entire hose reel is protected by a UV-protective canopy.
4. Hardened Pump Parts: Pump casing, impeller, and suction cover are treated with a
special material that is designed to resist wear.
5. Rear Spray Bar: The spray bar option is not designed for slurry application, but for the
dispersion of liquids for dust control, watering, feeding, and washing applications. Rear
spray bar is arranged so that operation is remotely controlled from the truck cab.
6. Air Flush System: The air flush option uses compressed air to purge any remaining mulch
slurry from the HydroSeeder
®
hose, the discharge boom, and the recirculation piping. To
maximize performance, all discharge plumbing should be purged after every load. The air
flush system provides a quick and easy means of purging without the need to acquire a
flush tank and an additional water supply.
PRE-START CHECK
The following safety check should be made to ensure operator safety:
1. Check condition of all mounting hardware that secures HydroSeeder
®
to truck frame.
2. Make sure bag cutter is in place and secure.
3. Inspect all railings, ensuring they are all in place and secure.
4. Make sure that all guards are in place.
5. With the ignition switch in the
ON
position, verify that the amber safety light, under
the operator’s platform, is flashing.