FINEPLACER
®
lambda
Rev-Nr. 1.1
28
•
Whatever you clamp into the tracks, its upper side's edges must be pressed
against the upper edge of the V-slots.
•
To meet the working plane with substrates placed on a heating plate or on a
substrate support plate, the positioning table has tracks that are continuously
adjustable for substrate thickness from 0 to 10 mm.
•
When the release button (34) is pressed (by your thumb), the front track (23)
can be moved in and out. To do this, hold it between your thumb and first and
middle fingers.
•
To position something correctly between the tracks, open the tracks as
described before, move the object first into the V-grooves of the rare track
after that close the tracks and let slip the object into the front track. As soon
as it is secured between the grooves, release the button (34), locking front
track and board in place.
•
To hold the substrate onto the heating plate, e.g. in the case of flexible
material, it may be equipped with an integrated vacuum holder.
4.1.3
Providing Suitable Placement Heads for the Pivot Arm
•
Make sure that the placer head is suitable for the height of your component.
Custom specified positioning heads are available, please ask your dealer.
•
Using the screw (21), the placer head (20) must be fixed so that its shaft is
inserted fully to meet the correct working height (z-position).
•
Check the correct mounting of the positioning head using the VAS.
4.1.4
Interconnection of the lambda
•
Ensure the voltage adjustment of the Placer Control Box (see label at the
back) corresponds to the mains voltage.
•
Connect and fasten the 25-pin cable from the Placer Control Box, connector
(38), to the support arm (71), connector (26). Take care not to confuse with
the computer cable!
•
Connect the foot switch (64) to connector (9) of the Placer Control Box.
•
Connect the pivot arm (27) signal cable plug (28) to socket (66) of the Placer
Control Box.
•
Connect the pivot arm vacuum connection hose filter (44) to socket HEAD
VACUUM (46) at the rear of the Placer Control Box.
•
Connect the table air hose plug (2) to the table air coupling (4) at the rear of
the support arm (71). Push in the fitting firmly until it clicks. To loosen it, push
back the knurled nut of the socket and pull out the fitting.
•
Connect the input end of the 3 mm vinyl hose (87) of the table air connector
(4) to the air OUTPUT connection fitting (7).