AT THE END OF THE WORK
At the end of the work, and before carrying out any type of maintenance, perform the following operations:
1. Select the “transfer” program (see “
”).
2. Take the appliance to the dedicated dirty water drainage area.
3. Carry out all the procedures listed in the paragraph “RECOMMENDED PERIODIC MAINTENANCE” (in the column “AT THE END OF THE
WORK”).
4.
Once the maintenance work is finished take the appliance to the designated storage place.
5. Secure the machine, see the section titled “
ATTENTION:
Park the machine in an enclosed place, on a flat surface, and at a safe distance from any objects that could either damage
it or be damaged due to contact with the machine itself.
ROUTINE MAINTENANCE
Before carrying out any routine maintenance operations, proceed as follows:
1. Take the machine to the maintenance area.
N.B.:
the place given over to this operation must comply with current environmental protection regulations.
2. Make sure the machine is in a safe condition (see chapter “
”).
CAUTION:
it is recommended to wear the appropriate PPE (Personal Protective Equipment), suitable for the work to be carried out.
34
INTERVAL
MACHINE COMPONENTS
PROCEDURE
DAIL
Y; BEFORE
A LONG PERIOD OF INACTIVITY
Squeegee
Clean the vacuum chamber; the squeegee rubber blades; the vacuum nozzle
(see “
”).
Debris hopper
Empty the debris hopper and clean inside (see “
Brush head brushes
Clean the brushes on the brush head body (see “
BODY BRUSHES (SCRUBBING VERSION)
”).
Clean the brushes on the brush head body (see “
BODY BRUSHES (SWEEPING VERSION)
”).
Clean the brush on the side brush head body (see “
Clean the side brushes (see “
CLEANING THE SIDE BRUSH (SWEEPING
Recovery tank
At the end of every working day, empty the recovery tank (see “
”).
At the end of every working day, after having emptied the recovery tank, clean the
CLEANING THE RECOVERY TANK FILTERS
”).
At the end of every working day, after emptying the recovery tank, clean the filter
in the detergent solution recycling system (see “
At the end of every working day, after having emptied the recovery tank, clean the
vacuum tube (see “
Solution tank
At the end of every working day, empty the solution tank (see “
WEEKL
Y
Machine water system
Clean the filter in the machine's water system (see “
”).
Squeegee rubber blades
Check that the rubber blades on the squeegee body are intact and inspect for
wear; if necessary, replace these (see “
Brush head brushes
Check that the brushes on the brush head body are intact and inspect for wear;
if necessary, replace these (see “
ASSEMBLING THE BRUSH HEAD BRUSHES
Check that the brushes on the brush head body are intact and inspect for wear;
if necessary, replace these (see “
ASSEMBLING THE BRUSH HEAD BRUSHES
MONTHLY
Squeegee rubber blade levelling
Check that the rubber blades on the squeegee body are level and if necessary,