9

Ready    [Green] 

Heater     [White] 

Touch 

  Pad   

 [Red] 

 

TABLE OF TECHNICAL DATA 

SW1 = time * 10 

SW3=temperature set 

SW2 = time * 1    

 

0 =  87 C 
1 =  88 C 
2 =  89 C 
3 =  90 C 
4 =  91 C 
5 =  92 C 
6 =  93 C 
7 =  94 C 
8 =  95 C 

Portion time =  
SW1 * 10 + SW2 
 
Min Time = 1 second even if SW1 and SW2 are set to 0 
 
Max Time is 30 Seconds

 

9 =  96 C

 

 

 

Error Messages 

Green LED

 

White LED RED 

LED Error 

Type 

Blink 

Blink Blink SYSTEM 

ERROR 

Blink 

Off Off Thermistor 

Short 

Blink 

Off 

On  

Thermistor Open 

Blink 

On  

Off 

Initial Fill Error 

Blink 

On  

On  

Fill Error 

Blink 

Blink Off  Boil 

Error 

Blink 

Blink 

On  

Heater Open 

Blink 

Off Blink 

Heater 

Shorted 

Blink 

On  

Blink 

Keyboard Error 

 

 
 

Error Descriptions 

SYSTEM ERROR 
 
Thermistor Short 
    Shorting out the thermistor will cause the thermistor error at once. 
 
Thermistor Open 
    Opening the thermistor will cause the thermistor error at once. 
 
Initial Fill Error 
    Tank has not filled in 6 minutes 
 
Fill Error 
    Tank does note re-fill after 1 minute 
 
Boil Error 
    If The heater is on and 
    Tank temperature < temperature tank was last off + 1 C and 
    Tank temperature > 92C 
 
Heater Open 
    If The heater is on and 
    Tank temperature < temperature tank was last off + 1 C and 
    Tank temperature < 92C 
 
Heater Shorted 
    If the heater is off and 
    The heater off time >= the temperature rise time (7 min) and 
    The tank temperature > the temperature last time on + 1 C 
 
Keyboard Error 
    1    Press and hold the button with unit idle. 
         After 3 seconds unit goes into proportional mode 
         As soon as unit begins to dispense a 45 second timer is started. 
         The unit will stop dispensing after the programmed timed. 
         if the button remains held for more than 45 seconds the unit  
         goes into keyboard error. 
    2.   Press and release then press to have a manual dispense. 
         Continue to hold the button, after 30 seconds the dispense will 
         stop. 45 Seconds after the dispense stops the unit goes into 
         keyboard error. 

 
 
 
 

Summary of Contents for HWB-2102 series

Page 1: ...ries commercial hot water dispensers Table of Contents Operator and User Section FETCO Hot Water Dispenser HWD_2102 2 Contact Information 2 Description Features 2 Operating Instructions 2 Technical an...

Page 2: ...lit proper dispense temperature is enabled When heating or reheating the green READY light will turn off and the HEATING light will display Dispense flow rate is given for typical 45psi 0 31mPa water...

Page 3: ...d Lift finger and reactivate after portion by retouching pad for next dispense portion Finger must be on pad to dispense To dispense for PORTION CONTROL Touch and Hold 1 Press and hold UNLOCK DISPENSE...

Page 4: ...pe of spray cleaner on the face panel of this equipment 3 Never use solvent or solvent based cleaner or petroleum based polish on this equipment 4 Dry the face of the HWD 2102 before turning on power...

Page 5: ...sec to maximum single dispense is 1200ml 40 5 ounces in 30seconds maximum dispense time Dimensions Utility Connections Designs materials specifications physical dimensions firmware and software protoc...

Page 6: ...water pressure is between 20 75 psig 138 517 kPa Cleaning Maintenance Daily 1 Check the drip tray and empty if necessary Quarterly 1 Inspect all fittings and hoses for leaks 2 Inspect inside of tank f...

Page 7: ...88 190 2 89 192 3 90 194 Lower Dials Marked S1 S2 Set dispense volume The two lower dials control the hot water volume to be delivered by setting the dispense time in seconds The timer dials are addi...

Page 8: ...ermistor error at once Blink On Off Initial fill error Tank has not filled in 6 minutes Blink On On Fill error Tank does not re fill after 1 minute Blink Blink Off Boil error If the heater is on and T...

Page 9: ...e Initial Fill Error Tank has not filled in 6 minutes Fill Error Tank does note re fill after 1 minute Boil Error If The heater is on and Tank temperature temperature tank was last off 1 C and Tank te...

Page 10: ...efore any cleaning procedure including wiping the exterior for appearance reasons Dry the exterior especially the face panel before turning on power WARNING 6 Do not apply any type of spray cleaner on...

Page 11: ...as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or authorized service personnel with the specified cord on...

Page 12: ...with capacity rated by local code or National Electrical Code for the current draw of this equipment Check serial number plate on right side for power requirements Locate unit away from source of hea...

Reviews: