9
Ready [Green]
Heater [White]
Touch
Pad
[Red]
TABLE OF TECHNICAL DATA
SW1 = time * 10
SW3=temperature set
SW2 = time * 1
0 = 87 C
1 = 88 C
2 = 89 C
3 = 90 C
4 = 91 C
5 = 92 C
6 = 93 C
7 = 94 C
8 = 95 C
Portion time =
SW1 * 10 + SW2
Min Time = 1 second even if SW1 and SW2 are set to 0
Max Time is 30 Seconds
9 = 96 C
Error Messages
Green LED
White LED RED
LED Error
Type
Blink
Blink Blink SYSTEM
ERROR
Blink
Off Off Thermistor
Short
Blink
Off
On
Thermistor Open
Blink
On
Off
Initial Fill Error
Blink
On
On
Fill Error
Blink
Blink Off Boil
Error
Blink
Blink
On
Heater Open
Blink
Off Blink
Heater
Shorted
Blink
On
Blink
Keyboard Error
Error Descriptions
SYSTEM ERROR
Thermistor Short
Shorting out the thermistor will cause the thermistor error at once.
Thermistor Open
Opening the thermistor will cause the thermistor error at once.
Initial Fill Error
Tank has not filled in 6 minutes
Fill Error
Tank does note re-fill after 1 minute
Boil Error
If The heater is on and
Tank temperature < temperature tank was last off + 1 C and
Tank temperature > 92C
Heater Open
If The heater is on and
Tank temperature < temperature tank was last off + 1 C and
Tank temperature < 92C
Heater Shorted
If the heater is off and
The heater off time >= the temperature rise time (7 min) and
The tank temperature > the temperature last time on + 1 C
Keyboard Error
1 Press and hold the button with unit idle.
After 3 seconds unit goes into proportional mode
As soon as unit begins to dispense a 45 second timer is started.
The unit will stop dispensing after the programmed timed.
if the button remains held for more than 45 seconds the unit
goes into keyboard error.
2. Press and release then press to have a manual dispense.
Continue to hold the button, after 30 seconds the dispense will
stop. 45 Seconds after the dispense stops the unit goes into
keyboard error.