CONTROL PANEL LAYOUT DIAGRAM FOR HWD_2102 HOT WATER DISPENSER 

 

Power Lamp

(Lit when unit is energized)

Ready Lamp

-Dispense will operate when lit,  

-Temperature is low when not lit

Heating Lamp

 For hot water tank

(is “ON” when heater is activated)

Sensor for Function Selector 

selects and activates selected option

Border of UNLOCK/DISPENSE pad will:

-after unlocking by first pressing pad

Æ

 

       glow white when ready to unlock 

 glow steady red when ready to dispense

Pulsates rapidly to show a fault state

 

Silicone Tap for hot water dispenser 

 

 

 

 

 

 

 

 
To dispense with MANUAL CONTROL

—[Press and hold

!] 

1) Press UNLOCK/DISPENSE pad for 1-3 seconds to unlock and activate dispensing system 

-Border of UNLOCK/DISPENSE pad will change: turning steady red signaling activation 

2) Remove finger from pad 

-Border of UNLOCK/DISPENSE pad will 

glow steady red: ready to dispense

 

3) Press center of UNLOCK/DISPENSE pad to dispense.  Keep finger on pad until dispense is complete.  

-Dispense automatically stops when time out is complete, or if finger is removed. 

Multiple dispenses are possible when the light bordering the UNLOCK/DISPENSE pad is steady and red colored 
Lift finger and reactivate after portion by retouching pad for next dispense portion.  Finger must be on pad to dispense. 

 

To dispense for PORTION CONTROL

—[Touch and 

Hold!] 

1) Press and hold UNLOCK/DISPENSE pad for 3 seconds to unlock and activate dispensing system 

-Border of UNLOCK/DISPENSE pad will change: and will rapidly strobe signaling activation 

2) Remove finger from pad 

-Selected portion will automatically complete 

3) If needed: tap center of UNLOCK/DISPENSE pad to stop dispense.  .  

-Dispense automatically stops when time out is complete, or if pad is tapped again. 

Æ

 Dispense is unlocked and will function only when border of UNLOCK/DISPENSE pad is steady red.  

 
The UNLOCK/DISPENSE pad rapidly flashes red if finger remains on it after dispensing and no water is dispensed. 
 
If finger remains on the UNLOCK/DISPENSE pad more than 30 seconds while rapidly flashing red-the controls “lock out” 
and READY LIGHT & HEATING LIGHT will flash rapidly to show a fault state.  All controls are disabled during fault state. 
 
To clear Fault State: 
Switch machine “OFF” for about ten seconds, and then toggle back “ON” (Control Reset)  

 

After controls initiate, hot water tank level and temperature are checked- then the “READY” light will activate. 

Æ

 This will take approximately 2 minutes for filled and heated unit; up to 20-30 minutes for a new and empty unit. 

Summary of Contents for HWB-2102 series

Page 1: ...ries commercial hot water dispensers Table of Contents Operator and User Section FETCO Hot Water Dispenser HWD_2102 2 Contact Information 2 Description Features 2 Operating Instructions 2 Technical an...

Page 2: ...lit proper dispense temperature is enabled When heating or reheating the green READY light will turn off and the HEATING light will display Dispense flow rate is given for typical 45psi 0 31mPa water...

Page 3: ...d Lift finger and reactivate after portion by retouching pad for next dispense portion Finger must be on pad to dispense To dispense for PORTION CONTROL Touch and Hold 1 Press and hold UNLOCK DISPENSE...

Page 4: ...pe of spray cleaner on the face panel of this equipment 3 Never use solvent or solvent based cleaner or petroleum based polish on this equipment 4 Dry the face of the HWD 2102 before turning on power...

Page 5: ...sec to maximum single dispense is 1200ml 40 5 ounces in 30seconds maximum dispense time Dimensions Utility Connections Designs materials specifications physical dimensions firmware and software protoc...

Page 6: ...water pressure is between 20 75 psig 138 517 kPa Cleaning Maintenance Daily 1 Check the drip tray and empty if necessary Quarterly 1 Inspect all fittings and hoses for leaks 2 Inspect inside of tank f...

Page 7: ...88 190 2 89 192 3 90 194 Lower Dials Marked S1 S2 Set dispense volume The two lower dials control the hot water volume to be delivered by setting the dispense time in seconds The timer dials are addi...

Page 8: ...ermistor error at once Blink On Off Initial fill error Tank has not filled in 6 minutes Blink On On Fill error Tank does not re fill after 1 minute Blink Blink Off Boil error If the heater is on and T...

Page 9: ...e Initial Fill Error Tank has not filled in 6 minutes Fill Error Tank does note re fill after 1 minute Boil Error If The heater is on and Tank temperature temperature tank was last off 1 C and Tank te...

Page 10: ...efore any cleaning procedure including wiping the exterior for appearance reasons Dry the exterior especially the face panel before turning on power WARNING 6 Do not apply any type of spray cleaner on...

Page 11: ...as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or authorized service personnel with the specified cord on...

Page 12: ...with capacity rated by local code or National Electrical Code for the current draw of this equipment Check serial number plate on right side for power requirements Locate unit away from source of hea...