background image

 

5

 

Specifications  

For qualified service technicians

 

 

EXPORT AND CE-Electrical Configurations 

Configuration 

Code 

Heater 

Configuration

 

Voltage

 

Phase

Wires

 

Electrical 

Connection

 

W

 

Maximum 

Amp draw

 

Flow Rate 

Per hour*

 

H210240CE 

1 X 3.2 KW 

230 

single  L ,N, PE 

 

3030 

13.8 31.0 

liters/8.2gal 

*Flow rate based on 55°F/13°C water mains supply

 and dispensing

 From (“READY” Light ON) 

Portion Control: factory calibrated at 5sec—the dispense portion of 200ml/6.8oz. 

Portion size is controlled by dispense time.  Range: 1 sec to maximum single dispense is 1200ml/40.5 ounces in 30seconds (maximum dispense time).

 

 
 

 
 

 
 

Dimensions & Utility Connections 

 
 

Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Weights and Capacities  

Brewer / Dispenser Model 

Weight 

(empty) 

Water tank  

Capacity 

Weight 

(filled) 

Hot Water Boiler HWD-2102 

8.6 kg/19 lb 

6.9 liter/1.8 gallon 

14.8 kg/32.6lb 

Water Requirements  

Pressure: 20-75 psig (0.138-0.517mPa)  (45/0.310 psi/kPa is preferred)  Minimum Flow Rate: 1½ gpm   
All commercial hot water dispensers to be supplied with filtered water

 

Water connection inlet: 3/8 inch male flare fitting.

 

Summary of Contents for HWB-2102 series

Page 1: ...ries commercial hot water dispensers Table of Contents Operator and User Section FETCO Hot Water Dispenser HWD_2102 2 Contact Information 2 Description Features 2 Operating Instructions 2 Technical an...

Page 2: ...lit proper dispense temperature is enabled When heating or reheating the green READY light will turn off and the HEATING light will display Dispense flow rate is given for typical 45psi 0 31mPa water...

Page 3: ...d Lift finger and reactivate after portion by retouching pad for next dispense portion Finger must be on pad to dispense To dispense for PORTION CONTROL Touch and Hold 1 Press and hold UNLOCK DISPENSE...

Page 4: ...pe of spray cleaner on the face panel of this equipment 3 Never use solvent or solvent based cleaner or petroleum based polish on this equipment 4 Dry the face of the HWD 2102 before turning on power...

Page 5: ...sec to maximum single dispense is 1200ml 40 5 ounces in 30seconds maximum dispense time Dimensions Utility Connections Designs materials specifications physical dimensions firmware and software protoc...

Page 6: ...water pressure is between 20 75 psig 138 517 kPa Cleaning Maintenance Daily 1 Check the drip tray and empty if necessary Quarterly 1 Inspect all fittings and hoses for leaks 2 Inspect inside of tank f...

Page 7: ...88 190 2 89 192 3 90 194 Lower Dials Marked S1 S2 Set dispense volume The two lower dials control the hot water volume to be delivered by setting the dispense time in seconds The timer dials are addi...

Page 8: ...ermistor error at once Blink On Off Initial fill error Tank has not filled in 6 minutes Blink On On Fill error Tank does not re fill after 1 minute Blink Blink Off Boil error If the heater is on and T...

Page 9: ...e Initial Fill Error Tank has not filled in 6 minutes Fill Error Tank does note re fill after 1 minute Boil Error If The heater is on and Tank temperature temperature tank was last off 1 C and Tank te...

Page 10: ...efore any cleaning procedure including wiping the exterior for appearance reasons Dry the exterior especially the face panel before turning on power WARNING 6 Do not apply any type of spray cleaner on...

Page 11: ...as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or authorized service personnel with the specified cord on...

Page 12: ...with capacity rated by local code or National Electrical Code for the current draw of this equipment Check serial number plate on right side for power requirements Locate unit away from source of hea...