background image

 

8

Ready    [Green] 

Heater     [White] 

Touch 

  Pad   

 [Red] 

 

 

 

ERROR Messages

 

 
The UNLOCK/DISPENSE pad rapidly flashes red if finger remains 
on it after dispensing and no water is dispensed.  
 
If finger remains on the UNLOCK/DISPENSE pad more than 35 
seconds while rapidly flashing red-the controls “lock out” and 
READY LIGHT & HEATING LIGHT will flash rapidly to show a fault 
state.  See keyboard errors 1 & 2 in chart below 
 

All controls are disabled during fault state. 

 
 

To clear Fault State: 

 
Switch machine “OFF” for about ten seconds, and then toggle back “ON” (Control 
Reset)   
 
After controls initiate, hot water tank level and temperature are checked- then the 
“READY” light will activate

  

Æ

 This will take approximately 2 minutes for filled and heated unit; up to 20-30 

minutes for a new and empty unit 
 
 

 
 

Color of LED-See above 

Error Messages 

“READY” “HEATER”

 

“TOUCH 

PAD”

 

Error type 

 

Green 

White 

Red 

 

 

Blink 

Blink  

Blink 

System error 

 

Blink Off  Off Thermistor 

short 

Shorting out the thermistor will cause the thermistor error at once 

Blink Off  On Thermistor 

open 

Opening the thermistor will cause the thermistor error at once 

Blink 

On 

Off 

Initial fill error 

Tank has not filled in 6 minutes 

Blink On  On Fill 

error 

Tank does not re-fill after 1 minute 

Blink Blink Off Boil 

error 

If the heater is on and 
 
 

Tank temperature 

<

 the temperature tank was last 

off + 1 C and  
the tank temperature 

92C 

Blink Blink On Heater 

open 

If the heater is on and 
 
 

Tank temperature < temperature tank was last off 
+ 1 C and  
the tank temperature 

92C 

Blink Off  Blink 

Heater 

shorted 

If the heater is supposed 
to be off and 
 

The heater off time >/=  the temperature rise time 
(7 min) 

and

 the tank temperature 

the 

temperature last time on + 1 C 

NOTE:  <

 

means less than

;    

means greater than

;   

</=

 

means less than or equal to

;  

>/=

 

means greater than or equal to

 

Keyboard error 1 

 1.    Press and hold the button with unit idle. 
After 3 seconds unit goes into proportional mode 
As soon as unit begins to dispense a 45 second timer is started the unit will 
stop dispensing after the programmed timed if the button remains held for 
more than 45 seconds the unit goes into keyboard error 

Blink On  Blink 

Keyboard error 2 

 2.   Press and release then press to have a manual dispense 
if the button remains held for more than 30 seconds-->the dispense will stop.   
45 Seconds after the dispense stops the unit goes into keyboard error 

 
 
 

Summary of Contents for HWB-2102 series

Page 1: ...ries commercial hot water dispensers Table of Contents Operator and User Section FETCO Hot Water Dispenser HWD_2102 2 Contact Information 2 Description Features 2 Operating Instructions 2 Technical an...

Page 2: ...lit proper dispense temperature is enabled When heating or reheating the green READY light will turn off and the HEATING light will display Dispense flow rate is given for typical 45psi 0 31mPa water...

Page 3: ...d Lift finger and reactivate after portion by retouching pad for next dispense portion Finger must be on pad to dispense To dispense for PORTION CONTROL Touch and Hold 1 Press and hold UNLOCK DISPENSE...

Page 4: ...pe of spray cleaner on the face panel of this equipment 3 Never use solvent or solvent based cleaner or petroleum based polish on this equipment 4 Dry the face of the HWD 2102 before turning on power...

Page 5: ...sec to maximum single dispense is 1200ml 40 5 ounces in 30seconds maximum dispense time Dimensions Utility Connections Designs materials specifications physical dimensions firmware and software protoc...

Page 6: ...water pressure is between 20 75 psig 138 517 kPa Cleaning Maintenance Daily 1 Check the drip tray and empty if necessary Quarterly 1 Inspect all fittings and hoses for leaks 2 Inspect inside of tank f...

Page 7: ...88 190 2 89 192 3 90 194 Lower Dials Marked S1 S2 Set dispense volume The two lower dials control the hot water volume to be delivered by setting the dispense time in seconds The timer dials are addi...

Page 8: ...ermistor error at once Blink On Off Initial fill error Tank has not filled in 6 minutes Blink On On Fill error Tank does not re fill after 1 minute Blink Blink Off Boil error If the heater is on and T...

Page 9: ...e Initial Fill Error Tank has not filled in 6 minutes Fill Error Tank does note re fill after 1 minute Boil Error If The heater is on and Tank temperature temperature tank was last off 1 C and Tank te...

Page 10: ...efore any cleaning procedure including wiping the exterior for appearance reasons Dry the exterior especially the face panel before turning on power WARNING 6 Do not apply any type of spray cleaner on...

Page 11: ...as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or authorized service personnel with the specified cord on...

Page 12: ...with capacity rated by local code or National Electrical Code for the current draw of this equipment Check serial number plate on right side for power requirements Locate unit away from source of hea...

Reviews: