background image

 

 

19

 

Brewing Problem 

Possible Cause 

Solution 

Spray head / brew basket drips 
either side or both 
 

MAJOR 

Cracked dispense tube/s 
(This problem starts out minor but 
gets steadily worse) 

-Replace both dispense tubes even if other side is not 
dripping  

 

Fill valve not sealing 
(Will drip even with power off.) 

-See next section - “Brewer won’t stop brewing”, “Bad or 
stuck fill valve”. 

Brewer won’t stop brewing

 

Dispense tube cracked  

-See “sprayhead drips MAJOR” above 

       (

not same as

 

high brew levels

Mechanical binding 
(brew handle stays down / brew light 
turns off at normal time) 

-Re-align the brew handle / brass sprayhead tower / and 
dispense tube into a straight line by moving brass tower 

 

Water pressure over 75psi 

-Place a water pressure regulator on the line and reduce to 
20-75 psi 

 

Dispense tube drive screw off. A 
2.5” screw that connects the handle 
to the dispense tube at the brass 
sprayhead tower. 
(handle returns up and brew lamp 
turns off but brewing continues) 

-Ensure that the drive screw is straight (can be 
straightened by hand while still in the brew handle) and 
reconnect to the dispense tube. The flange that the drive 
screw engages MUST be held flat against the brass 
sprayhead tower, without being able to back out. 

 

Water level probe bad or encrusted 
with lime. 
(causes brewer to continue filling hot 
water tank which will overflow into 
the brew baskets) 

-Clean lime build up on the probe tip 
and/or tank wall. (Holding the probe wire (green) from the 
probe end to the body of the brewer should stop the fill if 
the probe is bad but the liquid level board is good) 

 

Bad liquid level control board 

-Replace the LLC board if grounding the probe end of the 
(green) probe wire to the body of brewer does not remove 
the voltage at the fill terminal on the LLC board. 

 

Bad or stuck fill valve 

-Rebuild or replace the fill valve if no voltage is on the coil 
(it is not magnetic) and it still passes water to the tank. 
(Disconnect the outlet side to see if it leaks water to the 
tank) 

Coffee tastes too strong

 

Incorrect dosage 

-Measure and confirm the correct amount of coffee 
required 

 

Short brew levels 

-See “Short brew levels”, above. 

 

Temperature Problem (brewer 
only) 

Possible Cause 

Solution 

See also LUXUS problems 

 

 

Brew water is cold / not hot enough, 
ready light is OFF. 

(Before proceeding, make sure water 
tank refills when water is dispensed. 
The brewer will not heat unless the 
tank is full.) 

No power to brewer. 

-Make sure power switch is on. 
-Reset machine circuit breaker. 
-Check power connection. (plug or hard wire connection). 
-Check building circuit breaker. (Always reset breaker by 
switching off, then on.) 

 

Defective liquid level control board.  
(No power to thermostat). 

-With power on, and water tank full, check LLC board for 
120 volts on brown wire and neutral.  Replace LLC board if 
there is no voltage. 

 

Bad connections on mercury relay.  
(No power to heaters). 

-Check relay for burned or loose connections.  Replace 
with high temperature connectors if necessary. 

 

Defective mercury relay.  
(No power to heaters). 

-Check input and output voltages on relay. 120 volts on 
blue wire (input) but no voltage out to heaters indicates a 
bad relay. 

 

Bad heating element/s.  
 

-Check amperage draw on heater wires. 0 amps = bad 
heater. 

Brew water is cold / not hot enough, 
ready light is   ON. 
 

Bad Thermostat 
(the thermostat believes that it is at 
set temperature) 

-Replace the thermostat and or thermal probe. It’s not 
possible to trouble shoot the probe. 

 

Low brew temperature setting on 
thermostat 

-See “Low brew temperature” under “

Weak Coffee”

 

section. 

Slow to recover temperature 

 

Brewers with more than one heater 
can have just one fail 

-Check amperage draw on heater wires. 0 amps = bad 
heater. 

(Ready light takes along time to come 
back on after brewing.) 

Hot water tank limed up 

-Remove access cover to the hot water tank and inspect 
for lime. Remove the brewer for shop de-liming if build up 
is thick. 

Boiling 

Thermostat set too high for altitude 
(Denver etc.) 

-Reduce temperature setting to 3 degrees below boiling at 
your altitude 

 

Defective thermostat 

-Replace the thermostat and or thermal probe. It’s not 
possible to trouble shoot the probe. 

 

Summary of Contents for CBS-61H

Page 1: ...formation 2 Product Description Features 2 Technical Data 2 Brewing Specification 2 Weights and Capacities 2 Electrical Configuration and Brewing Efficiency 3 Dimensions Utility Connections 4 Installa...

Page 2: ...ercury type power contactor Two level tank drain system Total serviceability from the front Technical Data Brewing Specification Brew Volume Temperature Full Batch 3 gal 11 4 lit 205 F inside water ta...

Page 3: ...e Configuration Connection Phase Wires KW Amp draw Cold Water Hot Water C62016 3 X 3000 watt 120 208 single 3 ground 6 9 33 3 5 6 12 9 120 220 single 3 ground 7 7 35 2 6 5 14 9 120 240 single 3 ground...

Page 4: ...4 Dimensions Utility Connections CBS 61H CBS 62H...

Page 5: ...are installing Verify that the brewer will fit in the space intended for it and that the counter or table will support the total weight of the brewer and dispensers when filled 2 The brewer s legs are...

Page 6: ...Within 6 seconds the hot water tank will begin filling until the water is sensed by the probe at the top of the tank 5 The heaters will be disabled by the control board until the tank is full 6 The br...

Page 7: ...so any residual hot water or coffee will be noticed by the operator Place a paper filter in each basket to be used Pour into the paper filter the appropriate amount of pre measured ground coffee The...

Page 8: ...ucet body is metal it will dissipate the beverage temperature over time This temperature loss is more noticeable with hot beverages than cold If a dispenser of hot coffee goes unused the first ounce o...

Page 9: ...ispense latch assembly When the brew handle is rotated from the stop to the brew position it pushes the plunger in the latch coil and closes the micro switch and the timer starts the timed cycle It al...

Page 10: ...m leaving it free of standing water Steam escaping from the brew tank through this tube inhibits the formation of lime in the brew system The dispense system is clean semi dry for all but the brief ti...

Page 11: ...asure the temperature again Repeat until the desired temperature is obtained Replace the cover s Effective April 1 2004 A new digital thermostat and temperature probe were introduced as a direct repla...

Page 12: ...setting of the dial before making any adjustments Turn the knob clockwise to increase and counter clockwise to decrease the timer setting On the dual portion timer the knob labeled T1 controls the fu...

Page 13: ...coffee grounds The bypass can be adjusted from 0 to 33 of the total brewing water Dual brewers CBS 62H have separate bypass valves on each side Unless requested at the time of order all brewers are s...

Page 14: ...aucet c ring 4 102052 faucet shank assembly 5 24009 faucet shank o ring x 6 12018 vent top plug 7 71017 sight gauge washer lower 8 71024 sight gauge cap 9 71018 sight gauge washer upper 6 9 102020 sig...

Page 15: ...37 Thermostat Temp probe Locknut 1 4 NSPL temp probe tank fitting 22 61 62 31036 Thermostat Temp probe tank Fitting 1 4 MPT x 1 4 comp 23 61 62 53015 thermostat temp probe 14 use with K033 digital the...

Page 16: ...rcury 35amp DP 120vac 208 240v 1ph brw 80 61 62 52025 Relay mercury 60amp TP 120vac 208 240v 3ph brw 80 61 62 52030 Relay mercury 35amp DP export 208 240v coil 80 61 62 52033 Relay mercury 30amp TP 12...

Page 17: ...59 61 65 64 63 92 90 91 83 82 81 60 76 DWG 701 015 1 2 3 4 5 8 9 10 6 7 7 11 13 12 14 15 27 22 28 29 17 26 43 42 40 41 33 39 33 32 35 36 38 34 30 31 16 18 35 37 73 71 72 74 94 57 58 93 89 80 77 23 24...

Page 18: ...rate is too low or fluctuates too much to support a full brew problem is worse in simultaneous brews Make sure brewer has a dedicated water line Ensure that the shut off valve is open all the way Nev...

Page 19: ...it leaks water to the tank Coffee tastes too strong Incorrect dosage Measure and confirm the correct amount of coffee required Short brew levels See Short brew levels above Temperature Problem brewer...

Page 20: ...Coffee not hot enough LUXUS not preheated before first brew of the day Preheat the LUXUS 1 2 full with hot water and let stand for 15 minutes Attempting to hold coffee too long Review discard times U...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ......

Reviews: