Troubleshooting 

Brewing Problem 

Possible Cause 

Solution 

Brew handle

 will not stay down 

Power switch off. 

-Turn switch on. 

 

No power to the brewer 
(Brewer lights are not illuminated) 

-Make sure the brewer is plugged in. 
-Check the wall circuit breaker / reset 
-Turn the brewer power switch off then back on (it has 
an internal breaker) 

 

Bad timer or dispense latch 
assembly. 
(Brew light 

does not 

come

 

on and 

handle won’t stay down) 

-Check for voltage reaching the timer from the dispense 
latch assembly if yes replace timer. If no, replace latch 
assy. 

 

Bad dispense latch assy. 
(Brew light 

does 

come on

 

and 

handle won’t stay down) 

-Replace the dispense latch assembly 

 

Bad dispense latch assembly 
(brewer buzzes when in brew cycle) 

-Replace the dispense latch assembly 

Brew handle

 stays down but no water is 

dispensed 

No water reaching the brewer 

-Make sure the shut off valve is open. 
-Check water line for kinks; replace line if necessary 
-Check to see if filter is clogged by changing it. 

Short brew levels  

EVERY BREW

 

 

Flow discs in spray heads in upside 
down 

-Reassemble spray heads - bumps on spray cutter face 

 with flange on flow disc facing 

 

 

Water filter clogged 

(See details in next section) 

 

Spray head clogged 

-Clean and or replace the sprayhead 

(

One or

 

Both sides

 are 

Timer/s are set too low 

-Advance timers to proper level. 

affected and levels are

 consistent

Incoming Voltage is too low for 
timers to function at proper time 
sequences 

-Reset wall circuit breaker as one side may drop out & 
not flag the breaker. 
-Call an electrician to find loose connections in the 
building 

Short brew levels  

SOME BREWS

  

 

Water filter clogged. 
(problem is worse during 
simultaneous brews) 

-Replace water filter 

 

Weak dispense latch assembly 
(usually buzzes during cycle) 

-Replace dispense latch assembly. 

(

One or

 

Both sides

 are affected and 

levels are 

erratic

Water pressure or flow rate is too 
low or fluctuates too much to 
support a full brew. 
(problem is worse in simultaneous 
brews) 

-Make sure brewer has a dedicated water line 
-Ensure that the shut off valve is open all the way (Never 
use needle saddle valves) 
-Increase the diameter of the water line to the brewer 
and or find stable source. 

Brew Time required to fill LUXUS are 
not the same for both sides

 

Brewer is not level 

-With an accurate level, level the brewer front to back 
and left to right by adjusting the feet. 

High brew levels    

EVERY BREW 

(overfills but does stop) 

Timer/s are set too high 

-Adjust timers down to appropriate level 

                               SOME BREWS 

Thermal server not empty 

-Empty the server and try again 

Brew basket or filter overflows 

 

-Call FETCO Service Dept. to discuss. 
    (800) 338-2699 

Weak Coffee

 

Spray head missing 

-Attach spray head assembly. 

 

Improper dose 

-Measure and confirm correct dose 

 

Filter papers 

-Make sure only one paper is used 

 

Cracked dispense tube 

-See  “spray head drips MAJOR”, below 

 

Low brew temperature 
(Temperature inside the hot water 
tank is set to 205

°

 F, the metal 

delivery system drops the temp.) 

-Adjust thermostat so the water stream measured at the 
bottom of the brew basket, 1/3 of the way through the 
brew cycle, equals 190 d or - 5 degrees 

Grounds not saturated

 

Spray head missing 

-Replace spray head 

 

Half batch used incorrectly 

-Use smaller “half batch” brew basket 

 

 

-Discourage half batch use  

 

 

-Investigate the need for a smaller brewer 

 

Water Softener in use 

-Move brewer water feed to a non-softened source. 

 

Degassing - extremely fresh coffee 

-Call FETCO Service Dept. to discuss. 
    (800) 338-2699 

No bypass

     EVERY BREW 

 

Bypass valve closed 

-Open bypass valve 

                       SOME BREWS

 

Flow disc wrong size or missing 

-Correct or replace flow disc 

Spray head / brew basket drips either 
side or both 
 

MINOR 

Condensation around the 
sprayhead area 

-Wipe sprayhead area after brewing; place an empty 
container under brew cone when not in use. 

 

Condensation from water tank 
dripping through dispense tube 

-Insert an empty brew basket and server under brew 
heads when not in use 

 

Summary of Contents for CBS-61H

Page 1: ...formation 2 Product Description Features 2 Technical Data 2 Brewing Specification 2 Weights and Capacities 2 Electrical Configuration and Brewing Efficiency 3 Dimensions Utility Connections 4 Installa...

Page 2: ...ercury type power contactor Two level tank drain system Total serviceability from the front Technical Data Brewing Specification Brew Volume Temperature Full Batch 3 gal 11 4 lit 205 F inside water ta...

Page 3: ...e Configuration Connection Phase Wires KW Amp draw Cold Water Hot Water C62016 3 X 3000 watt 120 208 single 3 ground 6 9 33 3 5 6 12 9 120 220 single 3 ground 7 7 35 2 6 5 14 9 120 240 single 3 ground...

Page 4: ...4 Dimensions Utility Connections CBS 61H CBS 62H...

Page 5: ...are installing Verify that the brewer will fit in the space intended for it and that the counter or table will support the total weight of the brewer and dispensers when filled 2 The brewer s legs are...

Page 6: ...Within 6 seconds the hot water tank will begin filling until the water is sensed by the probe at the top of the tank 5 The heaters will be disabled by the control board until the tank is full 6 The br...

Page 7: ...so any residual hot water or coffee will be noticed by the operator Place a paper filter in each basket to be used Pour into the paper filter the appropriate amount of pre measured ground coffee The...

Page 8: ...ucet body is metal it will dissipate the beverage temperature over time This temperature loss is more noticeable with hot beverages than cold If a dispenser of hot coffee goes unused the first ounce o...

Page 9: ...ispense latch assembly When the brew handle is rotated from the stop to the brew position it pushes the plunger in the latch coil and closes the micro switch and the timer starts the timed cycle It al...

Page 10: ...m leaving it free of standing water Steam escaping from the brew tank through this tube inhibits the formation of lime in the brew system The dispense system is clean semi dry for all but the brief ti...

Page 11: ...asure the temperature again Repeat until the desired temperature is obtained Replace the cover s Effective April 1 2004 A new digital thermostat and temperature probe were introduced as a direct repla...

Page 12: ...setting of the dial before making any adjustments Turn the knob clockwise to increase and counter clockwise to decrease the timer setting On the dual portion timer the knob labeled T1 controls the fu...

Page 13: ...coffee grounds The bypass can be adjusted from 0 to 33 of the total brewing water Dual brewers CBS 62H have separate bypass valves on each side Unless requested at the time of order all brewers are s...

Page 14: ...aucet c ring 4 102052 faucet shank assembly 5 24009 faucet shank o ring x 6 12018 vent top plug 7 71017 sight gauge washer lower 8 71024 sight gauge cap 9 71018 sight gauge washer upper 6 9 102020 sig...

Page 15: ...37 Thermostat Temp probe Locknut 1 4 NSPL temp probe tank fitting 22 61 62 31036 Thermostat Temp probe tank Fitting 1 4 MPT x 1 4 comp 23 61 62 53015 thermostat temp probe 14 use with K033 digital the...

Page 16: ...rcury 35amp DP 120vac 208 240v 1ph brw 80 61 62 52025 Relay mercury 60amp TP 120vac 208 240v 3ph brw 80 61 62 52030 Relay mercury 35amp DP export 208 240v coil 80 61 62 52033 Relay mercury 30amp TP 12...

Page 17: ...59 61 65 64 63 92 90 91 83 82 81 60 76 DWG 701 015 1 2 3 4 5 8 9 10 6 7 7 11 13 12 14 15 27 22 28 29 17 26 43 42 40 41 33 39 33 32 35 36 38 34 30 31 16 18 35 37 73 71 72 74 94 57 58 93 89 80 77 23 24...

Page 18: ...rate is too low or fluctuates too much to support a full brew problem is worse in simultaneous brews Make sure brewer has a dedicated water line Ensure that the shut off valve is open all the way Nev...

Page 19: ...it leaks water to the tank Coffee tastes too strong Incorrect dosage Measure and confirm the correct amount of coffee required Short brew levels See Short brew levels above Temperature Problem brewer...

Page 20: ...Coffee not hot enough LUXUS not preheated before first brew of the day Preheat the LUXUS 1 2 full with hot water and let stand for 15 minutes Attempting to hold coffee too long Review discard times U...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ......

Reviews: