10
A bypass valve and tube are connected to the sprayhead. This valve directs brew water around the outside edge of
the filter paper. The by-pass valve is shipped in the closed position from the factory. Each time the valve is
adjusted, the brew volume is affected. Adjustment of the by-pass valve is for flavor only.
When the timer circuit releases the brew latch, the dispense tube pops back above the hot water level. The
remaining brew water drains from the dispense system leaving it free of standing water. Steam escaping from the
brew tank through this tube inhibits the formation of lime in the brew system.
The dispense system is clean & semi dry for all but the brief time required for the brew cycle. This eliminates any
chance of lime build-up affecting the brew cycle.
It is very easy to dislodge the dispense tube seals while servicing the dispense system. If you see it leaking
profusely, remove the nut and dispense tube. Reset the seal fully into the recess and carefully insert the dispense
tube. Then secure the locknut before you back the tube into position. (See detailed instructions on page 10.
Mechanical Illustration - Dispense System