20
LUXUS TPD-1.5 Problem
Possible Cause
Solution
LUXUS leaking from the base
Overflow of coffee, or water from
cleaning running down the side and
collecting in the black plastic base
(1.5 gallon LUXUS only)
-Remove the plastic base (it slips on and off) wipe the
interior and plastic base dry and reassemble. Monitor brew
practices & do not clean containers in sinks or dishwashers
Bad O-ring gasket behind
faucet shank
(1.5 & 3 gallon LUXUS)
-Remove the faucet, then unbolt the faucet shank from the
LUXUS and replace the O-ring.
LUXUS leaking from sight gauge
Brew level set too high
-Adjust timers for proper level
Sight gauge cap not tight
-Tighten gauge cap (show operators how this could have
been loosened when the vent cap was opened)
Lower gasket missing or bad
-Replace and or discourage casual cleaning practices
Coffee not hot enough
LUXUS not preheated before first
brew of the day
-Preheat the LUXUS 1/2 full with hot water and let stand for
15 minutes
Attempting to hold coffee too long.
-Review discard times
Using 1/2 batch on regular basis
-Encourage full batch use except at end of day or shift.
Explore the need for smaller brewers
Judging temperature from a sample
that is too small, taken from an
infrequently used LUXUS
-A small amount of coffee in the faucet body will cool in
about 15 minutes.
Drip from faucet
Blockage in faucet
(hair from cleaning brush, coffee
oils, etc.)
-Remove faucet bonnet (top part with handle attached) and
clean seat cup and faucet body. Clean on regular basis
Faucet seat cup
-Remove faucet bonnet (top part with handle attached) and
replace seat cup. Stained cups are OK cracked or brittle
are not.
Coffee won’t dispense
Vents closed on top of gauge tube
and or twist lock cover
-Open vents (vents are closed only for transporting the
servers or to extend holding times prior to serving coffee)