SLG−Z−...
Festo SLG−Z−... 0512a English
26
7. Check during the test run to see if the
following points need to be modified:
The swivel−in time of the stop lever
(unrestricted the stop lever will strike
in the mid−position the slide of the
SLG−...).
Position of the proximity switches
Adjusting the stop lever.
The stop lever must be locked only on
the side which does not face the plate.
The following setting ranges are possible:
Type
SLG−Z−8−...
SLG−Z−12−...
SLG−Z−18−...
Distance A
min
2.5 mm
3.7 mm
Distance A
max
4.2 mm
5.4 mm
Tightening torque
2,9 Nm
5,9 Nm
Fig.25
Modifications may only be undertaken when the slide is at a stand.
8. Conclude the test run.
6
Operation
Using the intermediate position module with a rubber buffer.
S
Take into account the fact that the end position will change after long periods
of operation due to the continuous deformation of the rubber buffer.
With diagonal or vertical fitting of the module.
S
Use the cushioning variant with shock absorber type YSRG−... .
Fig.24
A