Conditions  of  use

Please  note

Malfunctioning  will  occur  if  the  device  is  not  used  correctly.

S

Make  sure  that  the  specifications  in  this  chapter  are  always  observed.

Only  in  this  way  can  you  ensure  that  the  product  functions  correctly  and
reliably.

S

Compare  the  maximum  values  specified  in  these  operating  instructions  with
your  actual  application  (e.g.  pressures,  forces,  torques,  temperatures,  masses,
speeds).

Only  if  the  loading  limits  are  observed  can  the  HMP−...−B  be  operated  in
accordance  with  the  relevant  safety  guidelines.

S

Remove  the  packing  except  for  the  adhesive  labels  on  the  compressed  air
connections  (to  prevent  dirt).

The  packing  is  intended  for  recycling  (except  for:  oiled  paper  which  must  be
disposed  of ).

S

Observe  the  ambient  conditions  at  your
location.

S

Make  sure  there  is  a  supply  of  correctly
prepared  compressed  (see  Technical
data).

Fig.3

40m

Summary of Contents for HMP-x-B Series

Page 1: ...de Bedienungs anleitung en Operating instructions Pneumatisches Linearmodul Pneumatic linear module HMP B 682 649 0408NH...

Page 2: ...Please note Umwelt Antipollution Zubeh r Accessories Einbau und Inbetriebnahme nur von qualifi ziertem Fachpersonal gem Bedienungs anleitung Fitting and commissioning to be carried out by qualified pe...

Page 3: ...HMP B Festo HMP B 0408NH Deutsch 3 Pneumatisches Linearmodul HMP BDeutsch 1 Bedienteile und Anschl sse 1 3 4 5 2 6 7 8 9 aJ aA aB aC 1 aD aE aF aG aH...

Page 4: ...t 8 Aussparung mit Profildichtung f r Sensorkabel 9 Abschlussdeckel mit 2 Schrauben M3 befestigt aJ Sichtfenster f r die Schaltzustandsanzeige der LED s max sechs Sensoren aA Befestigungsalternativen...

Page 5: ...rn Die Zuf hrung der elektrischen Kabel erfolgt durch eine Profilausspa rung 8 am Enddeckel des Linearmoduls Der Abschlussdeckel HMP AD EL ist ein Erg nzungsmodul zum Linearmodul HMP Der Anschluss der...

Page 6: ...z B Dr cke Kr fte Momente Temperaturen Massen Geschwin digkeiten Nur die Einhaltung der Belastungsgrenzen erm glicht ein Betreiben des Linear moduls HMP B gem der einschl gigen Sicherheitsrichtlinien...

Page 7: ...ch digt die Lebensdauerschmierung S Bel ften Sie die Anlage insgesamt lang sam bis zum Betriebsdruck Dann erfolgen Bewegungen der Aktorik ausschlie lich kontrolliert Zur langsamen Einschaltbel ftung d...

Page 8: ...HMP B so dass alle Bedienteile erreichbar sind S W hlen Sie eine Befestigungsm glichkeit aus folgender Tabelle Direktbefestigung auf Grundfl che nur HMP 16 20 Nutensteinbefestigung seitlich auf Grundf...

Page 9: ...agerf hrung S Stellen Sie sicher dass der Massen schwerpunkt der Nutzlast innerhalb des zul ssigen Montagebereichs liegt siehe Kapitel Kennlinien Zur Verminderung von Schwingungen S Platzieren Sie den...

Page 10: ...erwenden Sie ein 5 2 Wegeventil in Grundstellung bel ftet Bei Einbau in senkrechter oder schr ger Lage S Pr fen Sie ob R ckschlagventile mit Ansteuerung vom Typ HGL mit hohem Durchfluss erforderlich s...

Page 11: ...gnetischen Teile In der Folge verschieben sich die Schaltpunkte der N herungsschalter dauerhaft S Gew hrleisten Sie die Abschirmung des Artikels gegen starke elektromagne tische St rfelder z B mit ein...

Page 12: ...getrennten Nuten gestaffelt positioniert werden 6 Entfernen Sie die Profildichtung Die Profilaussparung im Enddeckel des Linearmoduls erm glicht es N herungs schalterkabel integriert wegzuf hren siehe...

Page 13: ...eines Kabelbinders Zugentlastung 7 Befestigen Sie den Abschlussdeckel 9 mit den beiliegenden Schrauben Montieren Sie den Kabelschutzschlauch am Abschlussdeckel HMP AD EL wie folgt 1 W hlen Sie die Ka...

Page 14: ...rnfalls schl gt der Kolben unge bremst in die mechanische Endlage Die Mindestabst nde L sind in folgender Tabelle zusammengefasst HMP 16 20 25 32 Ma Lout ausfahrend 19 5 mm 27 mm 0 5 mm Ma Lin einfahr...

Page 15: ...s der Anschlag den Sto d mpferkopf ber hrt dann weiter um die L nge X des Sto d mpferhubs HMP 16 20 25 32 L nge X 12 mm 18 mm 24 mm Bild 28 5 Alle vier Anschlagschrauben wieder mit einem Anzugsdrehmom...

Page 16: ...chieben Sie das F hrungsrohr des Linear moduls HMP B in die eingefahrene Endlage Dabei dr cken Sie bei HMP KP die Handbet tigung der Klemmeinheit aH 2 Bel ften Sie die Druckluftanschl sse zuerst der e...

Page 17: ...ehe Tabelle 3 L sen Sie die Klemmschrauben aE um 2 Umdrehungen 4 Drehen Sie die Sto d mpferh lse und Sto d mpfer mit Gabelschl ssel an bJ bis die gew nschte Endlagenposition erreicht ist Maximalwerte...

Page 18: ...ssige Ein Ausfahrzeit t in Abh n gigkeit der Nutzlast entnehmen Sie bitte dem Diagramm im Kapitel Kennlinien Ohne hart anzuschlagen soll die Nutzlast die Endlage sicher erreichen Bei Verwendung der Li...

Page 19: ...Sie den D mpfungsweg der nun eingestellt ist S Vergleichen Sie den D mpfungsweg der Ersteinstellung mit dem jetzigen D mpfungsweg Ohne hart anzuschlagen soll die Nutzlast die Endlage sicher erreichen...

Page 20: ...Bauteile des Linearmoduls HMP gem Tabelle Entfettete Oberfl chen der F hrungsschiene W lzlager des F hrungsrohrs Bauteil Schmierintervall Bei Bedarf Alle 5000 km Laufstrecke sp testens alle 3 Jahre Sc...

Page 21: ...S Pr fen Sie ob die Schmier Pr fintervalle verk rzt werden m ssen Das kann notwendig sein im Falle von hoher Temperaturbelastung starkem Schmutzanfall N he fettl sender Fl ssigkeiten oder D mpfe 9 Au...

Page 22: ...g ein 7 Drehen Sie die Klemmschrauben wieder fest HMP 16 20 25 32 Nm 2 9 5 9 Bild 41 8 Drehen Sie die Kontermutter des Sto d mpfers wieder fest Das Anzugsdrehmoment betr gt HMP 16 20 25 32 Nm 5 20 35...

Page 23: ...l ABP 5 Befestigungselemente HMB Adapterbausatz HMA Verbindungselemente HMS Zentrierh lsen ZBH Nutensteine NST NSTL Kabelschutzschlauch MKR MKG Verschraubung MK V Gegenmutter MKM Sammelkabel KHMP 1 8x...

Page 24: ...netischen Werkstoffen einsetzen LED am HMP EL leuchtet nicht Anschlussfehler Verkabelung siehe Kapitel Einbau elektrisch Unzul ssigeKabelbiegung Zul Kabelbiegeradiuseinhalten Jumpereinstellungam HMP E...

Page 25: ...Zylinder Einbaulage Beliebig Medium Gefilterte ge lte oder unge lte Druckluft Filterfeinheit min 40 m bei Geschwindigkeiten bis max 1 m s ge lte Druckluft zul ssig bei Geschwindigkeiten ber 1 m s zwi...

Page 26: ...h sta tisch nur bei HMP AD EL MKR PG 21 45 mm MKR PG 29 50 mm MKG 20 PG 21 130 mm MKG 23 PG 29 155 mm MKG 37 PG 29 205 mm Schutzart IP40 Werkstoffe Zylinderprofil Frontplatte Abschlussdeckel Lagerdeck...

Page 27: ...HMP B Festo HMP B 0408NH Deutsch 27 13 Kennlinien Die Ein Ausfahrzeit Grenzwerte t ms in Abh ngigkeit der Nutzlast m kg bei max Hub bei geringerem Hub siehe Katalogangaben Bild 47...

Page 28: ...MP B Festo HMP B 0408NH Deutsch 28 Die Montagebereichs Grenzen f r den Nutzlastschwerpunkt bezogen auf die Mittelachse des F hrungsrohrs Grauer Kreis Montagebereich f r schwingungsarmen Betrieb Bild 4...

Page 29: ...HMP B Festo HMP B 0408NH English 29 Pneumatic linear module HMP BEnglish 1 Operating parts and connections 1 3 4 5 2 6 7 8 9 aJ aA aB aC 1 aD aE aF aG aH...

Page 30: ...eal for sensor cable 9 End cover fastened with 2 M3 screws aJ Viewing window for the switching status display of the LEDs max six sensors aA Methods of fastening the work load Dovetail profile Grooves...

Page 31: ...elec tric cables are connected through a profile recess 8 on the end cover of the linear module The end cover HMP AD EL is a supplementary module for the linear module type HMP The electric cables are...

Page 32: ...structions with your actual application e g pressures forces torques temperatures masses speeds Only if the loading limits are observed can the HMP B be operated in accordance with the relevant safety...

Page 33: ...ricated compressed air will damage the service life lubrication S Pressurize your complete system slowly until the operating pressure is reached All movements of the actuators will then be controlled...

Page 34: ...t all operating parts are accessible S Select one of the fastening possibilities listed in the following table Direct fastening on ground surface only HMP 16 20 Sliding block fastening on the side on...

Page 35: ...e roller bearing guide S Make sure that the centre of gravity of the mass lies within the permitted mounting range see chapter Characteristic curves Reducing vibrations S Place the centre of gravity o...

Page 36: ...S Use a 5 2 way valve pressurized in basic position If fitted in a vertical or sloping position S Check whether non return valves with control of type HGL with high flow rate are necessary Otherwise t...

Page 37: ...ization of the ferromagnetic parts As a consequence the switching points of the proximity switches will be permanently shifted S Make sure that the product is screened against strong electromagnetic i...

Page 38: ...in separate grooves permit a short switching sequence 6 Remove the profile seal The profile recess in the end cover of the linear module provides an exit for the proximity switch cables grouped togeth...

Page 39: ...with the aid of the cable binder strain relief 7 Fasten the end cover 9 with the screws provided Fit the protective cable tube on the end cover type HMP AD EL as follows 1 Select the cable exit openin...

Page 40: ...strike unbraked against the mechanical end position The minimum distances L are listed in the following table HMP 16 20 25 32 DimensionLout extending 19 5 mm 27 mm 0 5 mm DimensionLin retracting 0 5 m...

Page 41: ...stop touches the head of the shock absorber then further over length X of the shock absorber stroke HMP 16 20 25 32 Length X 12 mm 18 mm 24 mm Fig 28 5 Tighten all four stop screws again with a tight...

Page 42: ...module type HMP B into the retracted end position In the case of the HMP KP press the manual override of the clamping unit aH 2 Pressurize the compressed air ports at first in the retracted end posit...

Page 43: ...torque see table 3 Loosen the locking screws aE by 2 turns 4 Turn the shock absorber sleeve and the shock absorber with a wrench at bJ until the desired end position is reached Note maximum values v...

Page 44: ...e permitted retracting extending time t as a factor of the work load can be found in the diagram in the chapter Characteris tic curves The work load should reach the end posi tion without knocking har...

Page 45: ...ushioning path which is now set S Compare the cushioning path of the first setting with the present cushioning path The work load should reach the end position without striking hard against it S Note...

Page 46: ...ordance with the table The ungreased surfaces of the guide tube The roller bearing of the guide tube Component Lubricating interval If required After every 5000 km run at the latest every 3 years Lubr...

Page 47: ...hapter Dismantling and repairs S Check whether lubrication testing must be carried out more frequently This may be necessary if the temperature loading is high there is excessive dirt there are fat so...

Page 48: ...ng sleeve with the shock absorber up to the marking 7 Tighten the locking screws again HMP 16 20 25 32 Nm 2 9 5 9 Fig 41 8 Tighten the locking nut of the shock absorber again The tightening torque is...

Page 49: ...ABP 5 Fasteningelements HMB Adapter kits HMA Connectingelements HMS Centringsleeves ZBH Slidingblocks NST NSTL Protective cable tube MKR MKG Screw connector MK V Lock nut MKM Common cable KHMP 1 8x0 2...

Page 50: ...aterials LED on the HMP EL does not Connection fault Cabling see chapter Fitting electric components does not light up Non permitted cable bends Observe permitted cable bending radius Jumper setting o...

Page 51: ...ium Filtered lubricated or non lubricated compressed air filter fineness min 40 m at speeds up to max 1 m s lubricated compressed air permitted at speeds over 1 m s always use lubricated com pressed a...

Page 52: ...ube static only with HMP AD EL MKR PG 21 45 mm MKR PG 29 50 mm MKG 20 PG 21 130 mm MKG 23 PG 29 155 mm MKG 37 PG 29 205 mm Protection class IP40 Materials Cylinder profile front plate end cover bearin...

Page 53: ...MP B Festo HMP B 0408NH English 53 13 Characteristic curves The retracting extending limit values t ms as a factor of the work load m kg at max stroke at less stroke see catalogue specifications Fig 4...

Page 54: ...Festo HMP B 0408NH English 54 The mounting range limit values for the work load centre of gravity related to the centre axis of the guide tube Grey circle Mounting range for vibration free operation F...

Page 55: ...HMP B Festo HMP B 0408NH 55...

Page 56: ...ion ou reproduction de ce document sous quelque forme que ce soit et toute exploitation ou communication de son contenu sont interdites sauf autorisation crite expresse Tout manquement cette r gle est...

Reviews: