HMP−...−B−...
Festo HMP−...−B−... 0408NH English
30
1
Methods of fastening the linear module:
Dovetail profile
Grooves for fastening
(on HMP−25/−32−...; additional for all
HMP−... on side surface)
Threaded hole and centering for
fastening (on HMP−16/−20−...)
2
Housing cover
3
Compressed air connections with one−way
flow control valves (exhaust restricted)
E = retracting, A = extending
4
Compressed air connection for clamping
unit (only with HMP−...−KP)
5
Recess for cable exit
6
Terminal strip for sensor cable
7
End cover support fastened with 3 M5
screws
8
Recess with profile seal for sensor cable
9
End cover fastened with 2 M3 screws
aJ
Viewing window for the switching status
display of the LEDs (max. six sensors)
aA
Methods of fastening the work load:
Dovetail profile
Grooves and through holes
(on HMP−25/−32−...)
Threaded holes with centering
aB
Grooves for proximity switches in the
sensor strip
aC
Shock absorber retainer with sleeve for end
position cushioning
aD
Lubrication nipple for roller bearing guide
(4x)
aE
Locking screws for the shock absorber
sleeve (accurate adjustment of the end
position)
aF
Stop retainer fastened with M5 screws
(accurate adjustment of the end position)
aG
Locking screws for the stop (accurate
adjustment of the end position)
aH
Manual override for the clamping unit
(only with HMP−...−KP)
Fig.1
Summary of Contents for HMP-x-B Series
Page 55: ...HMP B Festo HMP B 0408NH 55...