4. Set the bit 1 in the control byte CPOS to the value 1 (START = 1).
–
The positioning job is started.
–
While the positioning job is being executed, bit 2 of the status byte SPOS has the value 0
(MC = 0).
–
As soon as the positioning job has ended, bit 2 of the status byte SPOS has the value 1 (MC = 1).
5. Reset the bit 1 in the control byte CPOS to the value 0 (START = 0) as soon as bit 1 in the status byte
SPOS has the value 1 (ACK = 1).