6
Operation
Festo – EXCM-10/-30-...-E-EN – 1612b – English
53
Response “Read CVE object”
Byte
Function
Data type
Description
0x00
Service ID
UINT08
0x10 = Read CVE object from controller
0x01
0x02
0x03
0x04
Message ID
UINT32
Message ID included in the request.
0x05
0x06
0x07
0x08
Data length
UINT32
The data length is dependent on the data type of the
read CVE object. The following applies:
Data length = 4 bytes + data type length
Example for UINT32:
Data length = 4 bytes + 4 bytes = 8 bytes
0x09
Acknowledge
UINT08
0 if everything is ok. All other values mean that the
object could not be read. A listing of possible causes of
error
è
0x0A
0x0B
0x0C
0x0D
Reserved
UINT32
Placeholder
0x0E
0x0F
Object index
UINT16
Index of the read CVE object.
0x10
Object subindex
UINT08
Subindex of the read CVE object.
0x11
Data type
UINT08
Data type of the read CVE object.
0x12
Data byte 1
corresponding
to data type of
the CVE object
Value of the read CVE object.
…
Data byte K
Tab. 6.14 Response “Read CVE object”