6
Operation
52
Festo – EXCM-10/-30-...-E-EN – 1612b – English
Request “Read CVE object”
Byte
Function
Data type
Description
0x00
Service ID
UINT08
0x10 = Read CVE object from controller
0x01
0x02
0x03
0x04
Message ID
UINT32
Message ID freely assignable by the application.
It is always sent back unchanged in the response. This
enables a unique assignment of the request and
response. The message ID can be used but is not
mandatory.
0x05
0x06
0x07
0x08
Data length
UINT32
Always 4 for this request
0x09
Acknowledge
UINT08
In the request, this field always remains empty
(initialise with 0).
0x0A
0x0B
0x0C
0x0D
Reserved
UINT32
Placeholder (initialise with 0).
0x0E
0x0F
Object index
UINT16
Index of the CVE object to be read.
0x10
Object subindex
UINT08
Subindex of the CVE object to be read.
0x11
Reserved
UINT08
Placeholder (initialise with 0).
Tab. 6.13 Request “Read CVE object”