CPS Gate
64
© Festo Didactic 8075265
During operation
Final status
or action
Mode
selector
position
Sequence
Description
LED status indication
Run
RUN
All IEC applications are processed and can be
stopped and started via the CODESYS IDE.
RFID
is active
NFC
not active in this case
Alternatively, NFC can be activated or
deactivated via an IEC application.
Stop
STOP
All existing IEC applications are stopped at
the end of the respective cycle and can no
longer be started via the CODESYS IDE.
NFC
NFC is a parameters configuring interface
–
it’s parameters can only be configured in the
voltage-
free state or in the “STOP” position
of the CODESYS run switch.
Reset CODESYS,
warm start
RESET
From > 1
to < 2 s
All IEC applications are reset by means of
“warm reset”.
Reset
RESET
> 4 s
Retain data are saved. The IEC applications
are then ended.
Reset
RESET
> 8 s
Reboot.