background image

1.4 Instructions on commissioning

WARNING
Please be careful if you modify the line assignment
of your CP system at a later stage.
After saving the string assignment or hardware con-
figuration, check the address assignment of your
higher-order system before you start user programs.

You thereby avoid:

– addressing errors if CP modules are incorrectly fitted.

With the CP field bus node, the new string assignment
must be saved if it has been modified (CP modules
added or removed). To do this press the SAVE button
on the node. Proceed as described in the manual "CP
system, installation and commissioning."

With the SPC200, the new hardware configuration must
also be saved if the string assignment has been
modifed. Proceed here as described in the manual for
the SPC200 or for WinPISA.

The operating status of the input module is shown by
the status LED on the CP connection (see following
table).

Status LED

1. Input module type CP-E16...-M...-...

1-22

CP-E16...-M...  9901b

Summary of Contents for CP-A08 Series

Page 1: ...Compact Performance CP Modules Electronics Input modules type CP E16 M Output modules type CP A08 M12...

Page 2: ...ng distribution and utilization of this docu ment as well as the communication of its contents to others without expressed authorization is prohibited Offenders will be held liable for the payment of...

Page 3: ...Part no 165 225 Title Manual Designation P BE CPEA GB II CP EA 9901b...

Page 4: ...allation 1 8 1 3 1 Connecting sensors 1 9 1 3 2 Connecting the input module 1 20 1 4 Instructions on commissioning 1 22 1 5 Technical specifications 1 26 2 Output module type CP A08 M12 2 1 Overview 2...

Page 5: ...on If used in conjunction with commercially available com ponents such as sensors and actuators the specified limit values for pressures temperatures electrical data torques etc must be observed Pleas...

Page 6: ...correctly These instructions are always printed in italics are framed and also signalled by pictograms Danger categories A distinction is made between the following WARNING This means that personal i...

Page 7: ...High voltages or undefined switching states of the elec tronic components which may influence connected cir cuits Electrostatically vulnerable components These will be damaged if you touch the contact...

Page 8: ...information on the method of operation fitting installation and com missioning of the following CP modules This manual refers to Input modules PNP CP E16 M8 CP E16 M12x2 CP E16 M12x2 5POL NPN CP E16N...

Page 9: ...valve terminal pneumatics type P BE CPV or type P BE CPA CP modules electronics Contents Special information on commissioning programming and diagnosing related to the node used Information on fittin...

Page 10: ...es service unit measuring system cylinders or linear drives Contents Installation commissioning and diagnosis with the SPC200 Standard components and modules Functions of the WinPISA software package...

Page 11: ...X CP EA 9901b...

Page 12: ...Chapter 1 Input module type CP E16 M 1 Input module type CP E16 M CP E16 M 9901b 1 1...

Page 13: ...E16 M 1 3 1 1 1 Display and connecting elements 1 4 1 2 Fitting 1 5 1 3 Installation 1 8 1 3 1 Connecting sensors 1 9 1 3 2 Connecting the input module 1 20 1 4 Instructions on commissioning 1 22 1 5...

Page 14: ...owing types Type Explanation CP E16 M12X2 CP E16N M12X2 Provides 16 PNP inputs sensor connections via 8 sockets with M12 thread Provides 16 NPN inputs sensor connections via 8 sockets with M12 thread...

Page 15: ...on for input type INPUT P for PNP inputs INPUT N for NPN inputs Sensor connections Green LED for status display one LED per input 4 5 6 7 8 9 Status LED green CP connection Protective cap Groove for i...

Page 16: ...ace area CP E16 M8 approx 150 mm x 66 mm CP E16 M12x2 approx 141 mm x 78 mm The diagram below shows the dimensions of the four threaded holes of screw size M4 Fitting on a wall 1 2 Input module type C...

Page 17: ...an support the weight of the module 2 Fit a hat rail support rail EN 50022 35x15 width 35 mm height 15 mm 3 Fasten the hat rail at least every 100 mm to the sup port surface 4 Let both fastenings on t...

Page 18: ...order to remove the module from a hat rail proceed as follows 1 Loosen the screws 2 Remove the housing 3 Use a screwdriver to prize open the hat rail and remove the module 1 2 Fastening Screwdriver F...

Page 19: ...plied load voltage You thereby avoid unintentional movements of the connected actuators undefined switching states of the electronic components WARNING Connect the earth cable on the side of the housi...

Page 20: ...th thread M12x1 CP E16 M8 Use the plug with union nut with thread M8x1 outer diameter max 12 mm KM8 M8 GSGD Fasten the plugs with the aid of the union nuts in order to avoid unintentional loosening e...

Page 21: ...ig 1 5 Pin assignment of input module type CP E16 M8 E Input Fig 1 6 Pin assignment of input module type CP E16 M12x2 Ex 3 Ex Ex 2 Pin 3 0V Pin 4 Ex Pin 1 24V Pin 1 24V Pin 4 Ex 2 Pin 3 0V Pin 2 Ex 3...

Page 22: ...onnection Fig 1 7 Pin assignment of input module type CP E16 M12x2 5POL Ex 3 Ex Ex 2 Pin 3 0V Pin 4 Ex Pin 1 24V Pin 1 24V Pin 4 Ex 2 Pin 3 0V Pin 2 Ex 3 Ex 1 Pin 2 Ex 1 1 1 1 Input module type CP E16...

Page 23: ...6 M8 PNP inputs 1 2 3 PLC I PC Ex e g via field bus Logic recognition Ex Green LED Ex Fig 1 8 Internal layout of input module CP E16 M8 24 V 10 15 2 Pin 1 Pin 2 Pin 3 3 1 0 V 1 Input module type CP E1...

Page 24: ...inputs Pin assignment Circuitry examples 1 2 3 Three wire sensor Two wire sensor Contact E Input Fig 1 9 Circuitry examples of input module CP E16 M8 Pin 1 24 V Pin 3 0 V Pin 2 Ex 2 3 1 1 Input modul...

Page 25: ...1 Green LED Ex 1 4 5 6 7 PLC I PC Ex e g via field bus Logic recognition Ex Green LED Ex Pin 5 only with type CP E16 M12x2 5POL Earth connection Fig 1 10 Internal layout of input module CP E16 M12x2...

Page 26: ...1 2 3 4 Pin 5 only with type CP E16 M12x2 5POL Earth connection 2 way distributor T piece Sensor 2 Ex 1 Sensor 1 Ex E Input Fig 1 11 Circuitry examples of input module CP E16 M12x2 3 4 2 Pin 1 24 V P...

Page 27: ...N M8 NPN inputs 1 2 3 PLC I PC Ex e g via field bus Logic recognition Ex Green LED Ex Fig 1 12 Internal layout of input module CP E16N M8 24 V 10 15 2 Pin 3 Pin 2 Pin 1 3 1 0 V 1 Input module type CP...

Page 28: ...nt Circuitry examples 1 2 3 Three wire sensor negative switching Two wire sensor negative switching Contact E Input Fig 1 13 Circuitry examples of input module CP E16N M8 Pin 1 24 V Pin 3 0 V Pin 2 Ex...

Page 29: ...field bus Logic recognition Ex 1 Green LED Ex 1 4 5 6 PLC I PC Ex e g via field bus Logic recognition Ex Green LED Ex Fig 1 14 Internal layout of input module CP E16N M12x2 24 V 10 15 Pin 3 Pin 2 5 3...

Page 30: ...try examples 1 2 3 2 way connector T piece Sensor 2 Ex 1 negative switching Sensor 1 Ex negative switching E Input Fig 1 15 Circuitry examples of input module CP E16N M12x2 1 2 3 Pin 1 24 V Pin 4 Ex P...

Page 31: ...o Max permitted string length Cable type Field bus node with CP connection 10 m KVI CP 1 or KVI CP 2 can be used as drag chain Axis interface type SPC AIF See manual for SPC200 type P BE SPC200 Powerb...

Page 32: ...ction of the higher order system field bus node axis interface or Powerbox the CP connection of an output module the CP connection of a valve terminal Further instructions can be found in the appropri...

Page 33: ...bus node the new string assignment must be saved if it has been modified CP modules added or removed To do this press the SAVE button on the node Proceed as described in the manual CP system installa...

Page 34: ...short circuit in sensor supply or In conjunction with CP node incorrect string assignment when voltage is switched on In conjunction with the SPC200 see user manual for the SPC200 None or Eliminate s...

Page 35: ...pply In conjunction with the CP field bus node Disconnect the input module briefly from the line or switch off the power supply at the node and then switch it on again In conjunction with the SPC200 P...

Page 36: ...1 signal and if there is a line assignment error PLEASE NOTE In conjunction with the CP field bus node If there is a line assignment error during the switch on phase the CP node will switch the power...

Page 37: ...ra Low Voltage Electromagnetic compatibility interference emission resistance to interference Tested as per EN 55011 limit value class B Tested as per EN 50082 2 Digital inputs Design 16 inputs as per...

Page 38: ...PELV power unit Protected Extra Low Voltage Electromagnetic compatibility interference emission resistance to interference Tested as per EN 55011 limit value class B Tested as per EN 50082 2 Digital i...

Page 39: ...1 Input module type CP E16 M 1 28 CP E16 M 9901b...

Page 40: ...Chapter 2 Output module type CP A08 M12 2 Output module type CP A08 M12 CP A08 M12 9901b 2 1...

Page 41: ...g 2 4 2 3 Installation 2 5 2 3 1 Connecting the actuators 2 6 2 3 2 Connecting the output module 2 13 2 3 3 Connecting the load voltage 2 14 2 4 Instructions on commissioning 2 17 2 5 Technical specif...

Page 42: ...utput module 1 2 3 4 Designation for output type OUTPUT P for PNP outputs OUTPUT N for NPN outputs CP connection Connections for actuators Yellow LED for status display one LED per output 5 6 7 8 9 0...

Page 43: ...ram below shows the dimensions for the four threaded holes for the M4 screws Fitting on a wall Fig 2 2 Fitting dimensions for output module CP A08 M12 Fitting onto a hat rail is undertaken in exactly...

Page 44: ...wer supply to all the output modules You thereby avoid unintentional movements of the connected actuators undefined switching states of the electronic components WARNING Connect the earth cable on the...

Page 45: ...Seal the unused sensor connections with the protective caps supplied Only then is compliance with class of protection IP65 ensured Pin assignment of the actuator connections CP A08 M12 PNP outputs n c...

Page 46: ...t module type CP A08 M12 5POL 1 2 Pin 5 Earth connection Internal connection in the module A Output n c not connected Fig 2 4 Pin assignment of output module CP A08 M12 5POL Ax 1 Pin 3 0V Pin 4 Ax Pin...

Page 47: ...n 0 2 4 6 Ax 1 connection 1 3 5 7 not connected 5 6 7 8 9 Yellow LED Green LED Diagnosis short circuit overload load voltage failure Actuator connection Pin 5 only with type CP A08 M12 5POL Earth conn...

Page 48: ...08 M12 5POL Earth connection With type CP A08 M12 not connected With type CP A08 M12 5POL connection 0 2 4 6 Ax 1 connection 1 3 5 7 not connected 3 4 5 Example 1 Example 2 Not permitted Fig 2 6 Circu...

Page 49: ...n Consuming device load must be supplied via this 24 V connection n c not connected A Output Fig 2 7 Pin assignment of output module CP A08N M12 Ax 1 Ax Pin 2 1 Pin 2 1 Pin 3 n c Pin 3 n c Pin 4 Ax Pi...

Page 50: ...cal isolation Not connected 5 6 7 8 Yellow LED Green LED Diagnosis short circuit overload load voltage failure Actuator connection Fig 2 8 Internal layout of output module CP A08N M12 Pin 3 Pin 4 Pin...

Page 51: ...connection Example 1 Example 2 Not permitted A Output n c not connected Consuming device load must be supplied via this 24 V connection Fig 2 9 Circuitry examples of output module CP A08N M12 Pin 1 2...

Page 52: ...P 1 or KVI CP 2 can be used as drag chain Axis interface type SPC AIF See manual for the SPC200 type P BE SPC200 Powerbox Type CP FB TBOX See manual for the higher order system Communication takes pla...

Page 53: ...otection against electric shock protection against direct and indirect contact in accordance with EN 60204 1 IEC 204 is guaranteed on Festo valve terminals Safety transformers with the adjacent design...

Page 54: ...ed 1 2 3 Earth connection pin 4 Earth connection on side of housing Load voltage can be switched off separately the operating voltage is supplied via the CP connection Fig 2 10 Pin assignment of load...

Page 55: ...output module and the earth connection at pin 4 have the same potential and that there are no equalizing currents You can then avoid interference caused by electromag netic influences PLEASE NOTE Che...

Page 56: ...string assignment must be saved if it has been modified CP modules added or removed To do this press the SAVE button on the node Proceed here as described in the manual CP system installation and com...

Page 57: ...or In conjunction with the CP node incorrect string assignment when power supply is switched on In conjunction with the SPC200 see user manual for the SPC200 None or eliminate short circuit overload...

Page 58: ...can replace the module by another of the same type during operation Replacing the CP module PLEASE NOTE Observe here the instructions in the manual for the higher order system e g CP system CP field b...

Page 59: ...oltage Electromagnetic compatibility interference emission resistance to interference Tested as per EN 55011 limit value class B Tested as per EN 50082 2 Load voltage connection rated value protected...

Page 60: ...mpatibility interference emission resistance to interference Tested as per EN 55011 limit value class A Tested as per EN 50082 2 Load voltage connection rated value protected against incorrect polarit...

Page 61: ...2 Output module type CP A08 M12 2 22 CP A08 M12 9901b...

Page 62: ...Appendix A Index A Index CP EA 9901b A 1...

Page 63: ...A Index A 2 CP EA 9901b...

Page 64: ...rcuitry examples of CP E16 M12x2 1 15 circuitry examples of CP E16 M8 1 13 circuitry examples of CP E16N M12x2 1 19 circuitry examples of CP E16N M8 1 17 connect to node 1 20 fitting on a wall 1 5 fit...

Page 65: ...CP A08N M12 2 12 fitting on a hat rail 2 4 fitting on a wall 2 4 internal layout of CP A08 M12 2 8 internal layout of CP A08N M12 2 11 P Pictograms VI Pin assignment inputs 1 10 NPN output 2 10 opera...

Page 66: ...input module 1 22 output module 2 17 T Target group V Technical specifications input module CP E16 M PNP 1 26 input module CP E16N M NPN 1 27 output module CP A08 M12 PNP 2 20 output module CP A08N M...

Page 67: ...A Index A 6 CP EA 9901b...

Reviews: