Status LED
Sequence
Operating status
Error treatment
LED lights up
Operating voltage applied
None
LED is out
- Operating voltage not
applied or no connection
to node
or
In conjunction with the CP
node
- incorrect string assignment
during operation
In conjunction with the
SPC200
- see user manual
for the SPC200
•
Check CP cable and
operating voltage
connection on the node
(pin 1)
or
•
correct string
assignment
•
See user manual
type P.BE-SPC200-...
LED flashes
quickly
- Test phase when power
supply is switched on
or
- short circuit/overload on
at least one output module
or
In conjunction with the CP
node
- incorrect string assignment
when power supply is
switched on
In conjunction with the
SPC200
- see user manual
for the SPC200
•
None
or
•
eliminate short
circuit/overload
and reset output
1)
or
•
check string assignment
2)
•
See user manual
type P.BE-SPC200-...
LED flashes
slowly
Load voltage failure
Restore load
voltage
1) If there is a short circuit/overload, all outputs of the module will be switched off
automatically. The error must be eliminated when the outputs are reset e.g. by user
program.
2) When the line assignment has been modified (CP modules added or removed), you must
store the new string assignment by pressing the SAVE button on the node.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
2. Output module type CP-A08...-M12-...
2-18
CP-A08...-M12 9901b
Summary of Contents for CP-A08 Series
Page 3: ...Part no 165 225 Title Manual Designation P BE CPEA GB II CP EA 9901b...
Page 11: ...X CP EA 9901b...
Page 12: ...Chapter 1 Input module type CP E16 M 1 Input module type CP E16 M CP E16 M 9901b 1 1...
Page 39: ...1 Input module type CP E16 M 1 28 CP E16 M 9901b...
Page 40: ...Chapter 2 Output module type CP A08 M12 2 Output module type CP A08 M12 CP A08 M12 9901b 2 1...
Page 61: ...2 Output module type CP A08 M12 2 22 CP A08 M12 9901b...
Page 62: ...Appendix A Index A Index CP EA 9901b A 1...
Page 63: ...A Index A 2 CP EA 9901b...
Page 67: ...A Index A 6 CP EA 9901b...