1.3.1 Connecting sensors
Use the following cable and plugs for connecting the
sensors.
Type
Plug
Cable
CP-E16-M12x2
SEA-GS-7 (PG7)
SEA-WS-7 (PG7)
KM12-DUO-...
CP-E16-M12x2-5POL
Use the plug with
union nut with
thread M12x1.
CP-E16-M8
Use the plug with
union nut with
thread M8x1
(outer diameter
max. 12 mm).
KM8-M8-GSGD-...
Fasten the plugs with the aid of the union nuts in order
to avoid unintentional loosening e.g. due to vibration.
Seal the unused sensor connections with the protective
caps supplied. Only then is compliance with class of
protection IP65 ensured.
1. Input module type CP-E16...-M...-...
CP-E16...-M... 9901b
1-9